Show simple item record

Author Shawki, G. S. A.en_US
Available date 2009-11-25T13:06:21Zen_US
Publication Date 1990en_US
Publication Name Engineering Journal of Qatar University
Citation Engineering Journal of Qatar University, 1990, Vol. 3, Pages 39-54.en_US
URI http://hdl.handle.net/10576/7976en_US
Abstract A novel machine designed and constructed to exert cyclic axial load for fatigue testing is herein reported. The main features of the test rig constitute the sinusoidal form of load wave and the stress - controlled, system of loading. Performance parameters comprise both static and alternating components of load as well as the frequency of load application. Typical results of tests run on steel C 60 and brass Ms 58 are presented. The experimentally determined endurance values, show consistency and good agreement with published data, thus, inspiring confidence in the test rig. The spectrum of material strength as influenced by cyclic loading, is herein displayed for the full range of the so-called "Dynamic Severity Criterion" first put forward by the author.en_US
Language enen_US
Publisher Qatar Universityen_US
Subject Mechanical Designen_US
Title A novel push-pull machine for testing High cycle fatigueen_US
Type Articleen_US
Pagination 39-54en_US
Volume Number 3en_US


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record