تصفح حسب الموضوع "Potentiometry"
السجلات المعروضة 1 -- 10 من 10
-
Cobalt phthalocyanine as a novel molecular recognition reagent for batch and flow injection potentiometric and spectrophotometric determination of anionic surfactants
( Elsevier B. V. , 2008 , Article)Cobalt(II) phthalocyanine [Co(II)Pc] is used as both an ionophore and chromogen for batch and flow injection potentiometric and spectrophotometric determination of anionic surfactants (SDS), respectively. The potentiometric ... -
Continuous potentiometric monitoring of viagra (sildenafil) in pharmaceutical preparations using novel membrane sensors
( Springer Nature , 2006 , Article)Two potentiometric sensors responsive to sildenafil citrate (SC) drug (the active component of viagra) are described, characterized, compared and used for drug assessment. The sensors are based on the use of the ion-association ... -
Flow injection potentiometric determination of harmine and harmaline hallucinogens
( Wiley-VCH Verlag , 1995 , Article)Flow injection analysis (FIA) systems incorporating potentiometric sensors for harmine and harmaline hallucinogens are described. The sensors are based on the use of harmine and harmaline tetraphenylborate or reineckate ... -
Kinetic Determination of Morphine in Illicit Powders, Using a Fluoride Selective Electrode, Based on Reaction with 1-Fluoro-2,4-dinitrobenzene
( Springer New York , 1996 , Article)A simple, accurate and selective method is described for the determination of morphine in illicit powders, based on monitoring the initial rate of fluoride ion liberation from the reaction of morphine with 1-fluoro-2,4-d ... -
Mercurimetric potentiometric determination of barbiturates using a solid-state iodide ion-selective electrode
( Taylor and Francis Inc. , 1997 , Article)A simple potentiometric method is described for mercurimetric titration of barbiturates using a solid-state iodide ion-selective electrode. The optimum titration conditions involve the use of a borate buffer of pH 9-10 as ... -
Novel biomedical sensors for flow injection potentiometric determination of creatinine in human serum
( Wiley-VCH Verlag , 2005 , Article)Coated-wire (CW) and tubular (Tu) type membrane sensors for creatinine are developed. These consist of creatinine tungstophosphate(CTP), creatinine molybdophosphate (CMP) and creatinine picrolonate (CPC) ion-pair complexes ... -
Novel miniaturized sensors for potentiometric batch and flow-injection analysis (FIA) of perchlorate in fireworks and propellants
( Elsevier B.V. , 2014 , Article)Three planar miniaturized perchlorate membrane sensors (3×5mm2) are prepared using a flexible Kaptan substrate coated with nitron-perchlorate (NT-ClO4) [sensor 1], methylene blue-perchlorate (MB-ClO4) [sensor II] and ... -
Novel thorium membrane sensors with anionic response based on trioctylphosphine oxide and toluate ionophores
( Wiley-VCH Verlag , 2008 , Article)Two novel potentiometric polymeric membrane sensors for rapid and accurate determination of thorium are described. These are based on the use of trioctylphosphine oxide (TOPO) and thorium toluate (Th-TA) as ionophores ... -
Plastic Membrane Electrodes for the Potentiometric Determination of Codeine in Pharmaceutical Preparations
( Springer New York , 1997 , Article)Four PVC membrane electrode systems responsive to codeinium cation are described. These electrodes are based on the use of the ion-association complexes of the codeinium cation with tetraphenylborate and reineckate ... -
Solid-state planar microsensors for selective potentiometric determination of ethylmorphine
( Marcel Dekker Inc. , 1999 , Article)The potentiometric performance characteristics of microelectronically fabricated solid-state planar ethylmorphine sensors based on silicon/silicon nitride substrate and a mixture of ethylmorphine-tetraphenylborate and ...