Show simple item record

AuthorSakib, Mahmud
AuthorKhandakar, Amith
AuthorChowdhury, Muhammad E.H.
AuthorAbdulMoniem, Mohammed
AuthorBin Ibne Reaz, Mamun
AuthorBin Mahbub, Zaid
AuthorSadasivuni, Kishor Kumar
AuthorMurugappan, M.
AuthorAlhatou, Mohammed
Available date2023-05-17T06:38:17Z
Publication Date2022-12-17
Publication NameSensors and Actuators A: Physical
Identifierhttp://dx.doi.org/10.1016/j.sna.2022.114092
CitationMahmud, S., Khandakar, A., Chowdhury, M. E., AbdulMoniem, M., Reaz, M. B. I., Mahbub, Z. B., ... & Alhatou, M. (2023). Fiber Bragg Gratings based smart insole to measure plantar pressure and temperature. Sensors and Actuators A: Physical, 350, 114092.
ISSN0924-4247
URIhttps://www.sciencedirect.com/science/article/pii/S0924424722007270
URIhttp://hdl.handle.net/10576/42825
AbstractVarious foot complications can be easily avoided by continuously monitoring plantar (foot sole) pressure and temperature at home. Systems which can simultaneously measure plantar pressure and temperature in real time are still scarce. In this work, the design, characterization, and implementation of a Fiber Bragg Gratings (FBG) based smart insole capable of simultaneously measuring plantar pressure and temperature has been reported. The instrumented insole was tested and verified during static and gait exercises. The paper also provides a comparison of the developed optoelectronic-based solution with a commercially available and widely used plantar pressure measurement and analysis system, and a lab-made electronic sensor-based solution for simultaneously recording plantar pressure and temperature. It was shown that even though the commercial plantar pressure acquisition system is very robust and highly precise due to many sensing units on the insole, the developed insole with a much smaller number of sensors can simultaneously acquire both plantar temperature and pressure with reasonable precision while displaying both foot pressure and temperature maps, and gait cycle plots in real-time with a development cost more than eight times lower than the manufacturing cost of the commercial solution. Our proposed optoelectronic-based solution is lightweight, uncomplicated but robust, and electronically safer than the commercial system. While the proposed system is far from its optimized form, we expect that our developed prototype will instigate other researchers in this domain to further explore optoelectronic-based solutions in real-time plantar pressure and temperature monitoring.
SponsorThis work was made possible by Qatar National Research Fund (QNRF) NPRP12S-0227–190164 and International Research Collaboration Co-Fund (IRCC) grant: IRCC-2021–001 and Universiti Kebangsaan Malaysia under Grant GUP-2021–019 and DPK-2021–001 . The open-access publication is supported by Qatar National Library (QNL).
Languageen
PublisherElsevier
SubjectFiber Bragg Gratings (FBG)
Plantar pressure
Plantar temperature
Plantar data acquisition
Real-time foot monitoring
Smart insoles
Optical fibers
Optoelectronics
TitleFiber Bragg Gratings based smart insole to measure plantar pressure and temperature
TypeArticle
Volume Number350
ESSN1873-3069


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record