Show simple item record

AuthorMohamad, Kharseh
AuthorAl-Khawaja, Mohammed
AuthorSuleiman, Muhannad T.
Available date2024-04-22T11:23:44Z
Publication Date2015-07-05
Publication NameGeothermics
Identifierhttp://dx.doi.org/10.1016/j.geothermics.2015.06.009
CitationKharseh, M., Al-Khawaja, M., & Suleiman, M. T. (2015). Potential of ground source heat pump systems in cooling-dominated environments: Residential buildings. Geothermics, 57, 104-110.
ISSN0375-6505
URIhttps://www.sciencedirect.com/science/article/pii/S0375650515000759
URIhttp://hdl.handle.net/10576/54065
AbstractFor countries in the Arabian Peninsula, air conditioning (A/C) systems account for 65% of the energy consumption, all of which comes from fossil fuel. Given the preparation for the 2022 World Cup, which will be held in Qatar, the possibility of implementing ground source heat pump systems (GSHP) for A/C purposes is investigated. Due to its high thermal performance, GSHP is considered a viable solution for reducing the energy consumption of heating and A/C systems. However, for the GSHP system to gain popularity in cooling-dominated environments such as Qatar, financial and environmental benefits need to be demonstrated. These benefits strongly depend on local design practices and standards and on working conditions.The work presented in this paper demonstrates the energy savings by using GSHP systems in the residential buildings sector in cooling-dominated environments. To achieve this goal, a common type of residential house located in Doha, Qatar, was chosen as a case study. The cooling load of the case study and the driving energy of two different air conditioning systems were estimated. The two considered air conditioning systems are the conventional air source heat pump system (reference system) and the ground source heat pump system. Finally, economic analysis of the proposed system for construction practices in Qatar was carried out.The performed analyses show that the reduction in the prime energy demand and, consequently, the greenhouse gas emissions for the GSHP is 19% when compared to the conventional air source heat pump system. In addition, the analyses show that for the local conditions in Qatar the payback time of GSHP is 9 years.
SponsorThis work was made possible by an NPRP 7-725-2-270 a grant from the Qatar National Research Fund (a member of The Qatar Foundation).
Languageen
PublisherElsevier
SubjectGround source heat pump
Economic viability
Hot climate
Air conditioning
Residential buildings
TitlePotential of ground source heat pump systems in cooling-dominated environments: Residential buildings
TypeArticle
Pagination104-110
Volume Number57


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record