Aluminium alloy 6061 T6 circular specimens were joined using TIG welding method. AlMg5 was used as filler. The corrosion behavior of welded and un-welded AA 6061 T6 was investigated using potentiodynamic and open circuit potential (OCP) measurements. Specimens were immersed in 3.5 (wt %) NaCl solution. Different zones with different corrosion properties were created as a result of the welding process. Results reveals that sever pitting corrosion has taken place on the heat affected zone (HAZ); the corrosion current of HAZ was increased. The measured potential of HAZ was more negative and largely fluctuated comparing to base metal (BM).