Effect of temperature and radial displacement cycles on soil?concrete interface properties using modified thermal borehole shear test
المؤلف | Xiao S. |
المؤلف | Suleiman M.T. |
المؤلف | Elzeiny R. |
المؤلف | Naito C. |
المؤلف | Neti S. |
المؤلف | Al-Khawaja M. |
تاريخ الإتاحة | 2020-03-18T08:11:11Z |
تاريخ النشر | 2018 |
اسم المنشور | Journal of Geotechnical and Geoenvironmental Engineering |
المصدر | Scopus |
الرقم المعياري الدولي للكتاب | 10900241 |
الملخص | Thermoactive geostructures (such as energy piles) are used for heating and cooling of buildings, which generate daily temperature changes and cycles in the geostructure and surrounding soil due to the intermittent operation of ground-source heat pumps. For energy piles, daily temperature changes and cycles result in cyclic displacement (expansion and contraction) in both the axial and radial directions of the pile and alter soil properties. In this study, a fully automated modified thermal borehole shear test (modified-TBST) device was utilized to perform tests in normally consolidated clayey soil to investigate the effects of temperature cycles (TC) and radial expansion/contraction displacement cycles (RDC) on the soil-energy pile interaction. In addition to directly measuring the shear stress?vertical displacement curves (t-z curves), the soil temperature at different locations and pore pressure were monitored. The fully automated modified-TBST device uses two concrete plates to simulate the pile surface with temperature and expansion/contraction controls. The tests were conducted with temperature changes (?T) at the soil?concrete interface of ?18, 0, and +20?C. The radial expansion and contraction displacements (?D) were +120 and ?120 ?m, respectively. Tests were conducted at different interface horizontal normal stresses and numbers of cycles. This paper focuses on summarizing the results of 16 tests: 6 conducted with temperature changes and cycles, 8 with radial displacement change and cycles only, and 4 with combined temperature and displacement cycles. When the soil? concrete interface was subjected to combined radial displacement and temperature cycles, the interface shear strength experienced significant changes. Therefore, it was concluded that the intermittent operation of heat pumps connected to energy piles installed in normally consolidated clayey soils has a significant effect on shaft resistance. ? 2018 American Society of Civil Engineers. |
راعي المشروع | This work was made possible by an NPRP 7-725-2-270 grant from the Qatar National Research Fund (a member of Qatar Foundation). The statements made herein are solely the responsibility of the authors. |
اللغة | en |
الناشر | American Society of Civil Engineers (ASCE) |
الموضوع | Energy piles Modified thermal borehole shear test Radial expansion/contraction Soil?energy pile interaction Temperature cycle Thermoactive geostructures |
النوع | Article |
رقم العدد | 7 |
رقم المجلد | 144 |
الملفات في هذه التسجيلة
الملفات | الحجم | الصيغة | العرض |
---|---|---|---|
لا توجد ملفات لها صلة بهذه التسجيلة. |
هذه التسجيلة تظهر في المجموعات التالية
-
الهندسة الميكانيكية والصناعية [1396 items ]