The effects of graft size and insertion site location during anterior cruciate ligament reconstruction on intercondylar notch impingement
المؤلف | Orsi, Alexander D. |
المؤلف | Canavan, Paul K. |
المؤلف | Vaziri, Askhan |
المؤلف | Goebel, Ruben |
المؤلف | Kapasi, Onaly A. |
المؤلف | Nayeb-Hashemia, Hamid |
تاريخ الإتاحة | 2020-09-20T08:35:37Z |
تاريخ النشر | 2017 |
اسم المنشور | Knee |
المصدر | Scopus |
الرقم المعياري الدولي للكتاب | 9680160 |
الملخص | Background Intercondylar notch impingement is detrimental to the anterior cruciate ligament (ACL). Notchplasty is a preventative remodeling procedure performed on the intercondylar notch during ACL reconstruction (ACLR). This study investigates how ACL graft geometry and both tibial and femoral insertion site location may affect ACL-intercondylar notch interactions post ACLR. A range of ACL graft sizes are reported during ACLR, from six millimeters to 11 mm in diameter. Variability of three millimeters in ACL insertion site location is reported during ACLR. This study aims to determine the post-operative effects of minor variations in graft size and insertion location on intercondylar notch impingement. Methods Several 3D finite element knee joint models were constructed using three ACL graft sizes and polar arrays of tibial and femoral insertion locations. Each model was subjected to flexion, tibial external rotation, and valgus motion. Impingement force and contact area between the ACL and intercondylar notch compared well with experimental cadaver data from literature. Results A three millimeter anterior-lateral tibial insertion site shift of the maximum size ACL increased impingement force by 242.9%. A three millimeter anterior-proximal femoral insertion site shift of the maximum size ACL increased impingement by 346.2%. Simulated notchplasty of five millimeters eliminated all impingement for the simulation with the greatest impingement. For the kinematics applied, small differences in graft size and insertion site location led to large increases in impingement force and contact area. Conclusions Minor surgical variations may increase ACL impingement. The results indicate that notchplasty reduces impingement during ACLR. Notchplasty may help to improve ACLR success rates. |
راعي المشروع | This report was made possible by an NPRP award [NPRP 5-086-2-031 ] from the Qatar National Research Fund (a member of The Qatar Foundation). |
اللغة | en |
الناشر | Elsevier B.V. |
الموضوع | Anterior cruciate ligament Graft size Impingement Insertion site Notchplasty |
النوع | Article |
الصفحات | 525-535 |
رقم العدد | 3 |
رقم المجلد | 24 |
تحقق من خيارات الوصول
الملفات في هذه التسجيلة
الملفات | الحجم | الصيغة | العرض |
---|---|---|---|
لا توجد ملفات لها صلة بهذه التسجيلة. |
هذه التسجيلة تظهر في المجموعات التالية
-
علوم الرياضة (pre 2023) [205 items ]