بحث بسيط
السجلات المعروضة 1451 -- 1460 من 1470
Poly(vinyl chloride) matrix membrane electrodes for manual and flow injection determination of metal azides
(
The Royal Society of Chemistry
, 1992 , Article)
Novel poly(vinyl chloride) matrix membrane electrodes for the azide ion are developed, electrochemically evaluated and used for manual and flow injection determinations of soluble and insoluble metal azides. These electrodes ...
Nitron tetrachloroaurate(III) electrodes with poly(vinyl chloride) and liquid membranes for the selective determination of gold
(
Elsevier
, 1991 , Article)
PVC matrix and liquid membrane electrodes have been developed for direct potentiometric determination of gold(III). The membranes incorporate nitron tetrachloroaurate(III) as electroactive material. Fast response for ...
Solid-state planar microsensors for selective potentiometric determination of ethylmorphine
(
Marcel Dekker Inc.
, 1999 , Article)
The potentiometric performance characteristics of microelectronically fabricated solid-state planar ethylmorphine sensors based on silicon/silicon nitride substrate and a mixture of ethylmorphine-tetraphenylborate and ...
Determination of amitriptyline, imipramine and orphenadrine in antidepressant drugs by potentiometry, spectrophotometry and atomic absorption spectrometry
(
Springer-Verlag
, 1993 , Article)
Methods are described for the determination of amitriptyline, imipramine and orphenadrine in some antidepressant drugs. They are based on a prior reaction with ammonium reineckate to form 1∶1 water-insoluble drugreineckate ...
Liquid and poly (vinyl chloride) matrix membrane electrodes for the selective determination of cocaine in illicit powders
(
Elsevier
, 1992 , Article)
The construction of liquid membrane and PVC matrix-type cocainium ion selective electrodes and their use for direct potentiometry and potentiometric titration of cocaine are described. The ion-pair complexes of cocaine ...
A New Poly (Vinyl Chloride) Matrix Membrane Electrode for Manual and Flow Injection Determination of Pilocarpine in Some Pharmaceutical Preparations
(
Taylor and Francis Inc.
, 1994 , Article)
A novel pilocarpinium ion selective membrane electrode is prepared, characterized and used in pharmaceutical analysis. The electrode system incorporates a PVC membrane with pilocarpine-reineckatc ion pair complex as an ...
Plastic Membrane Electrodes for the Potentiometric Determination of Codeine in Pharmaceutical Preparations
(
Springer New York
, 1997 , Article)
Four PVC membrane electrode systems responsive to codeinium cation are described. These electrodes are based on the use of the ion-association complexes of the codeinium cation with tetraphenylborate and reineckate ...
Kinetic Determination of Morphine in Illicit Powders, Using a Fluoride Selective Electrode, Based on Reaction with 1-Fluoro-2,4-dinitrobenzene
(
Springer New York
, 1996 , Article)
A simple, accurate and selective method is described for the determination of morphine in illicit powders, based on monitoring the initial rate of fluoride ion liberation from the reaction of morphine with 1-fluoro-2,4-d ...
Constituents of plants growing in Qatar XVII anti-inflammatory and cytotoxic activities of extracts of thirty indigenous species
(
Taylor & Francis
, 1990 , Article)
Thirty plants, indigenous to Qatar, were extracted separately with hexane, chloroform and ethanol. The dried extracts were examined for potential anti-inflammatory activities both in vitro by their ability to inhibit ...
Inhibition of the acid corrosion of iron with haloacetic acids
(
Scientific Publishers of India
, 1997 , Article)
The efficiency of chloro, dichloro, trichloro, bromo, and iodoacetic acids as inhibitors for acid corrosion of iron was studied using polarization technique. A significant retardation of the corrosion rate is observed in ...