Flow injection potentiometric determination of harmine and harmaline hallucinogens
(
Wiley-VCH Verlag
, 1995 , Article)
Flow injection analysis (FIA) systems incorporating potentiometric sensors for harmine and harmaline hallucinogens are described. The sensors are based on the use of harmine and harmaline tetraphenylborate or reineckate ...
Membrane solubilization in erythrocytes as a measure of radiation exposure to fast neutrons
(
IOP Publishing
, 1999 , Article)
Membrane solubilization and osmotic fragility of rat erythrocytes irradiated in vivo with fast neutron fluences ranging from 106 to 5 x 107 n cm-2 using a 252Cf source were measured instantaneously using a light scattering ...
Three-dimensional finite element analysis of permanent magnet brushless DC motor drives - Status of the state of the art
(
IEEE
, 1996 , Article)
This paper reviews recent advances in the state of the art of applying three-dimensional finite-element (3-D-FE) magnetic field computation techniques to the analysis and quantification of parameters and performance of ...
Liquid and poly (vinyl chloride) matrix membrane electrodes for the selective determination of cocaine in illicit powders
(
Elsevier
, 1992 , Article)
The construction of liquid membrane and PVC matrix-type cocainium ion selective electrodes and their use for direct potentiometry and potentiometric titration of cocaine are described. The ion-pair complexes of cocaine ...
Eutrophication in the coastal waters of Alexandria following the increase in phosphorus load
(
Parlar Scientific Publications
, 1996 , Article)
Samples from the coastal waters of Alexandria during 1991-1993 indicate a remarkable increase in the phosphorus load from 870 to 1140 kg y-1 compared to 567 kg y-1 in 1986 raising the average phosphorus from 1.01 to 1.47 ...
Dissolved copper, cadmium and lead in the coastal waters of Qatar, Arabian Gulf
(
National Institute of Science Communication and Information Resources (NISCAIR)
, 1997 , Article)
The concentrations of Cu, Pb and Cd have been determined in the exclusive economic zone of Qatar, Arabian Gulf during December 1993. Cathodic stripping voltammetry (CSV) was used both before and after UV destruction of ...
Plastic Membrane Electrodes for the Potentiometric Determination of Codeine in Pharmaceutical Preparations
(
Springer New York
, 1997 , Article)
Four PVC membrane electrode systems responsive to codeinium cation are described. These electrodes are based on the use of the ion-association complexes of the codeinium cation with tetraphenylborate and reineckate ...
Modeling and experimental verification of the performance of a skew mounted permanent magnet brushless DC motor drive with parameters computed from 3D-FE magnetic field solutions
(
IEEE
, 1994 , Article)
This paper contains a comparison between actual laboratory-measured performance of a brushless dc motor drive system, with skewed permanent magnet mounts on its rotor, and two computer-simulated motor drive system performance ...
Kinetic Determination of Morphine in Illicit Powders, Using a Fluoride Selective Electrode, Based on Reaction with 1-Fluoro-2,4-dinitrobenzene
(
Springer New York
, 1996 , Article)
A simple, accurate and selective method is described for the determination of morphine in illicit powders, based on monitoring the initial rate of fluoride ion liberation from the reaction of morphine with 1-fluoro-2,4-d ...
Three dimensional magnetic field computation by a coupled vector-scalar potential method in brushless DC motors with skewed permanent magnet mounts - the no-load and load results
(
IEEE
, 1994 , Article)
The coupled magnetic vector potential-magnetic scalar potential (CMVP-MSP) method of computation of 3D magnetic fields by finite elements (3D-FE), whose theoretical development and formulation were detailed in a companion ...