Assessment of fault-ride through capability of grid-connected brushless DFIG wind turbines
(
Institution of Engineering and Technology
, 2011 , Conference Paper)
DFIGs are reported to suffer serious reliability problems due to the presence of slip-rings, brushes and gearbox. These disadvantages encouraged several research groups to investigate the viability of employing single-frame ...
An active damping technique for a current source inverter employing a virtual negative inductance
(2010 , Conference Paper)
A grid connected CSI requires a CL filter stage. In this work, the isolation transformer leakage inductance constitutes this filter inductance. This CL filter is lightly damped for efficiency constraints. Hence, it is ...
Inverter-based versus synchronous-based distributed generation; Fault current limitation and protection issues
(
IEEE
, 2010 , Conference Paper)
The contribution of distributed generation (DG) to network fault levels depends heavily on the technology employed. In the case of directly connected rotating machines the fault behavior is well established; with synchronous ...
Fault ride-through capability enhancement based on flywheel energy storage system for wind farms connected via VSC high voltage DC transmission
(
Institution of Engineering and Technology
, 2012 , Conference Paper)
This paper proposes a recovery strategy for wind energy-fed voltage source converter high voltage DC transmission systems, capable of maintaining power balance between the AC and DC sides during different AC faults. This ...
Single phase grid connected current source inverter: Mitigation of oscillating power effect on the grid current
(
Institution of Engineering and Technology
, 2011 , Conference Paper)
Although voltage source inverters (VSIs) are the most common DC-AC grid-tied converters, current source inverters (CSIs) are considered to be promising candidate, thanks to their low THD voltages/currents and inherent ...
Modular multilevel structure of a high power dual active bridge DC transformer with stepped two-level output
(
Institute of Electrical and Electronics Engineers Inc.
, 2014 , Conference Paper)
This paper addresses the issues of dc voltage matching and dc fault protection in potential super-grids. An approach for high power dc-dc conversion is proposed and analyzed. A front-to-front connection of modular-multilevel ...
Sinusoidal PWM modulation technique of five-phase current-source-converters with controlled modulation index
(
Institute of Electrical and Electronics Engineers Inc.
, 2014 , Conference Paper)
Applications such as multiphase machine drives and wind energy conversion systems are normally based on voltage source converters (VSCs) which feature a convenient and familiar control scheme. In high-power medium voltage ...
Active and reactive power management of photovoltaic-based interline dynamic voltage restorer in low voltage distribution networks
(
IEEE Computer Society
, 2012 , Conference Paper)
A dynamic voltage restorer (DVR) is a series connected device that can support the voltage at existing critical loads during voltage sags. Voltage restoration may need active and/or reactive power injection into the ...
Iterated unscented Kalman filter-based maximum power point tracking for photovoltaic applications
(2013 , Conference Paper)
One of main challenges in harvesting power from a PV source is maximum power point tracking (MPPT). This is due to the nonlinear behaviour and characteristics of PV arrays. Conventional MPPT techniques usually utilize a ...
Harmonic rejection using multi-synchronous reference frame technique for CSI-based distributed generation with grid voltage distortion
(
IEEE
, 2011 , Conference Paper)
In the midst of the growing penetration of renewable energy resources and Distributed Generation (DG), power quality is one of the main concerns. Achieving low total harmonic distortion (THD) of exported current using low ...