Search
Now showing items 1-10 of 54
Finite-Control-Set Model Predictive Control for Grid-Connected Packed-U-Cells Multilevel Inverter
(
Institute of Electrical and Electronics Engineers Inc.
, 2016 , Article)
This paper presents a finite-control-set model predictive control (FCS-MPC) for grid-tied packed U cells (PUC) multilevel inverter (MLI). The system under study consists of a single-phase 3-cells PUC inverter connected to ...
Non-linear backstepping control of five-phase IM drive at low speed conditions-experimental implementation
(
ISA - Instrumentation, Systems, and Automation Society
, 2016 , Article)
In this paper non-linear backstepping control (BSC) is employed for high performance five-phase induction motor drive for low speed operation. The traditional control approaches such as direct torque control and indirect ...
Elimination of reverse recovery effects associated with CoolMOS devices employing current source inverter topology
(
IET
, 2012 , Conference Paper)
MOSFET transistors are continuously being an essential part of power electronic converters due to their low switching losses at high switching frequencies. However, the traditional power MOSFET suffers from a relatively ...
High-performance adaptive Perturb and observe MPPT technique for photovoltaic-based microgrids
(
IEEE
, 2011 , Article)
Solar photovoltaic (PV) energy has witnessed double-digit growth in the past decade. The penetration of PV systems as distributed generators in low-voltage grids has also seen significant attention. In addition, the need ...
Flywheel energy storage system based on boost DC-AC converter
(
http://dx.doi.org/10.1049/cp.2011.0194
, 2011 , Conference Paper)
An additional DC-DC boost converter is used in conventional configuration of Flywheel Energy Storage System (FESS) to regulate the output voltage during flywheel low speeds. This paper presents a new FESS based on the boost ...
Simplified generic on-line PWM technique for single phase grid connected current source inverters
(
Institute of Electrical and Electronics Engineers Inc.
, 2012 , Conference Paper)
Mandatory restrictions for a current source inverter's (CSI's) proper operation, like continuity of the DC link current, complicate the corresponding PWM generation especially in the case of single phase systems. Classical ...
Single phase grid connected current source inverter: Mitigation of oscillating power effect on the grid current
(
Institution of Engineering and Technology
, 2011 , Conference Paper)
Although voltage source inverters (VSIs) are the most common DC-AC grid-tied converters, current source inverters (CSIs) are considered to be promising candidate, thanks to their low THD voltages/currents and inherent ...
Studying the effect of over-modulation on the output voltage of three-phase single-stage grid-connected boost inverter
(
Elsevier B.V.
, 2013 , Article)
Voltage boosting is very essential issue in renewable-energy fed applications. The classical two-stage power conversion process is typically used to interface the renewable energy sources to the grid. For better efficiency, ...
A simple active-power control technique for grid-connected three-phase inverters at unity power factor
(
IEEE Computer Society
, 2013 , Conference Paper)
This paper presents a simple active-power control technique for low voltage grid-connected three-phase inverters with zero injected reactive power (unity power factor at grid). Two versions of the proposed controller are ...
Performance of a five-phase boost inverter-fed submersible induction machine
(2013 , Conference Paper)
An electrical submersible pump (ESP) motor is preferably fed from a low voltage variable-frequency drive (VFD) followed by a step-up transformer. The motor and drive connection through a long feeder usually causes over ...