Search
Now showing items 101-110 of 147
Multiple-module high-gain high-voltage DCDC transformers for offshore wind energy systems
(
IEEE
, 2011 , Article)
Renewable energy sources, such as offshore wind farms, require high voltage gains in order to interface with power transmission networks. These conversions are normally made using bulky, complex, and costly transformers ...
Effect of current harmonic injection on constant rotor volume multiphase induction machine stators: A comparative study
(
IEEE
, 2012 , Article)
Although torque enhancement in multiphase induction machines using harmonic current injection has been addressed in the literature, a detailed assessment of the effect of this enhancement on the design parameters of ...
Comparative evaluation of four quasi-square wave fed multiphase induction machines
(
IEEE
, 2011 , Conference Paper)
Multiphase winding structures provide induction machines with favorable fault tolerant characteristics. Medium voltage drives have also benefited from the favorable application characteristics of multiphase machines, as ...
Assessment of fault-ride through capability of grid-connected brushless DFIG wind turbines
(
Institution of Engineering and Technology
, 2011 , Conference Paper)
DFIGs are reported to suffer serious reliability problems due to the presence of slip-rings, brushes and gearbox. These disadvantages encouraged several research groups to investigate the viability of employing single-frame ...
An active damping technique for a current source inverter employing a virtual negative inductance
(2010 , Conference Paper)
A grid connected CSI requires a CL filter stage. In this work, the isolation transformer leakage inductance constitutes this filter inductance. This CL filter is lightly damped for efficiency constraints. Hence, it is ...
Inverter-based versus synchronous-based distributed generation; Fault current limitation and protection issues
(
IEEE
, 2010 , Conference Paper)
The contribution of distributed generation (DG) to network fault levels depends heavily on the technology employed. In the case of directly connected rotating machines the fault behavior is well established; with synchronous ...
Investigation of inter feeder power flow regulator: Load sharing mode
(2010 , Article)
The Inter feeder Power Flow Regulator (IFPFR) proposed in this paper consists of several voltage source inverters with common dc bus; each inverter is connected in series with one of different independent distribution ...
Ride-through capability of grid-connected brushless cascade DFIG wind turbines in faulty grid conditions-A comparative study
(
IEEE
, 2013 , Article)
Doubly-fed induction generator (DFIG)-based wind turbines (WTs) are reported to suffer reliability problems due to the presence of slip-rings, brushes, and the gearbox. These disadvantages encouraged several research groups ...
Optimum power transmission-based droop control design for multi-terminal HVDC of offshore wind farms
(
IEEE
, 2013 , Article)
Power generation through wind is expected to play a major role in the world's future energy portfolio. Nevertheless, wind power integration remains a challenging research area due to the special characteristics of wind ...
Fault ride-through capability enhancement based on flywheel energy storage system for wind farms connected via VSC high voltage DC transmission
(
Institution of Engineering and Technology
, 2012 , Conference Paper)
This paper proposes a recovery strategy for wind energy-fed voltage source converter high voltage DC transmission systems, capable of maintaining power balance between the AC and DC sides during different AC faults. This ...