بحث بسيط
السجلات المعروضة 121 -- 130 من 147
An improved performance direct-drive permanent magnet wind generator using a novel single-layer winding layout
(
IEEE
, 2013 , Article)
Direct-drive permanent magnet (PM) generators have become a strong contender in medium and large rating wind energy conversion systems as they not only provide higher efficiency and annual energy production, but also reduce ...
Vector control of multiphase induction machine under open-circuit phase faults
(
IEEE Computer SocietyIEEE
, 2013 , Conference Paper)
Multiphase induction machine is normally controlled using rotor field oriented vector control. Under phase(s) loss, the machine currents can be optimally controlled to satisfy certain optimization criteria. In this paper, ...
Studying the effect of over-modulation on the output voltage of three-phase single-stage grid-connected boost inverter
(
Elsevier B.V.
, 2013 , Article)
Voltage boosting is very essential issue in renewable-energy fed applications. The classical two-stage power conversion process is typically used to interface the renewable energy sources to the grid. For better efficiency, ...
An adaptive PR controller for inverter-based distribution generation with active damped LCL filter
(
IEEE
, 2013 , Conference Paper)
The fact distribution generation (DG) importance is growing rapidly in the recent years where the coupling between DG sources and the grid is done through inverters where exporting low distorted currents and high quality ...
Performance assessment of renewable energy-fed three-phase grid-connected voltage source converters and boost inverters during DC side faults
(
IEEEIEEE
, 2013 , Conference Paper)
In renewable energy-fed grid-connected applications, voltage source converters (VSC) offer high flexibility and system controllability features. In addition to the stepped down nature of its output voltage, the VSC is ...
A simple active-power control technique for grid-connected three-phase inverters at unity power factor
(
IEEE Computer Society
, 2013 , Conference Paper)
This paper presents a simple active-power control technique for low voltage grid-connected three-phase inverters with zero injected reactive power (unity power factor at grid). Two versions of the proposed controller are ...
A modified capacitor voltage control algorithm for suppressing the effect of measurement noise on grid-connected Z-source inverters controllers
(
http://dx.doi.org/10.1109/IECON.2013.6699136
, 2013 , Conference Paper)
Inverters are considered the orbit of research objectives for safe and reliable grid interface. Amongst the conventional inverters known as suitable candidates for gird connection in the last two decades, Z-source inverter ...
A novel open-stator-winding DFIM flywheel architecture for renewable energy applications
(
IEEE
, 2013 , Conference Paper)
Energy storage is becoming a basic component of modern renewable power plants, especially wind farms. For several considerations, local wind turbine (WT) energy storage is preferred. Flywheel energy storage is among the ...
Brushless doubly fed induction machine as a variable frequency transformer
(
IEEE
, 2012 , Conference Paper)
Variable frequency transformer (VFT) has been recently used as an alternative to HVDC to control power flow between asynchronous networks. VFT consumes less reactive power than a back-to-back HVDC system, provides faster ...
DC bus control of an advanced flywheel energy storage kinetic traction system for electrified railway industry
(
IEEE
, 2013 , Conference Paper)
The evolution of public transportation exhibits high potential nowadays due to the consistent demand of clean transportation with low pollution rates. Therefore electrified railway systems become viable with their ...