Synchrophasor-based backup distance protection of multi-terminal transmission lines
(
Institution of Engineering and Technology
, 2016 , Article)
The distance protection of multi-terminal transmission lines need to be redesigned due to possible changes in the backup protection emanating from probable infeed currents produced from tapped transmission lines. Furthermore, ...
Negative-Sequence Network Based Fault Location Scheme for Double-Circuit Multi-Terminal Transmission Lines
(
Institute of Electrical and Electronics Engineers Inc.
, 2019 , Article)
The fault resistance and infeeded currents from tapped transmission lines are the two main challenges to establish correct fault location estimation in multi-terminal transmission lines. Also, fault location estimation in ...
Nonlinear stochastic modeling for optimal dispatch of distributed energy resources in active distribution grids including reactive power
(
Elsevier B.V.
, 2019 , Article)
This paper deals with energy storage system (ESS) in active distribution networks. The purpose is to install ESSs on the grid to minimize network losses. The problem is expressed as an optimization programming to minimize ...
Risk-constrained scheduling of solar Stirling engine based industrial continuous heat treatment furnace
(
Elsevier
, 2018 , Article)
This paper presents a novel framework for designing and optimal scheduling of an air source heat pump based industrial continuous heat treatment furnace (ICHTF) which is driven by a solar Stirling engine and a wind turbine. ...
A Monitoring Technique for Reversed Power Flow Detection with High PV Penetration Level
(
Institute of Electrical and Electronics Engineers Inc.
, 2015 , Article)
The integration of renewable energy resources (RESs) in power systems poses many research challenges. Research shows that the RES output may exceed the consumed power during the day. Consequently, the direction of the power ...
An impedance-based method for distribution system monitoring
(
Institute of Electrical and Electronics Engineers Inc.
, 2018 , Article)
This paper presents a new approach in monitoring of a power distribution system. It uses the bus voltage and injected current to extract the apparent impedance seen from the measuring unit location. Then the apparent ...
A secondary voltage regulation approach for Hydro-Québec in transmission level
(
Elsevier
, 2015 , Article)
This paper presents a secondary voltage control that applies discrete controllers to regulate the voltage in the Hydro-Québec power network. Firstly, an artificial intelligence methodology is presented for partitioning the ...
Control technique for enhancing the stable operation of distributed generation units within a microgrid
(
Elsevier
, 2015 , Article)
This paper describes a control technique for enhancing the stable operation of distributed generation (DG) units based on renewable energy sources, during islanding and grid-connected modes. The Passivity-based control ...
Distance-differential protection of transmission lines connected to wind farms
(
Elsevier Ltd
, 2017 , Article)
Distance relays are often used in the protection of the transmission lines connected to the wind farms. The distance relay using the transmission line impedance measurement identifies the type and location of the fault. ...
Adaptive algorithm for transmission line protection in the presence of UPFC
(
Elsevier Ltd
, 2017 , Article)
The presence of flexible ac transmission system (FACTS) controllers in transmission lines causes mal-operation of distance relays. The series-shunt FACTS devices have larger influence on the performance of the relays compare ...