Novel thorium membrane sensors with anionic response based on trioctylphosphine oxide and toluate ionophores
المؤلف | Hassan, Saad S.M. |
المؤلف | Elnemma, Eman M. |
المؤلف | Attawiya, Amr M. Y. |
تاريخ الإتاحة | 2024-03-04T08:58:28Z |
تاريخ النشر | 2008 |
اسم المنشور | Electroanalysis |
المصدر | Scopus |
الرقم المعياري الدولي للكتاب | 1040-0397 |
الملخص | Two novel potentiometric polymeric membrane sensors for rapid and accurate determination of thorium are described. These are based on the use of trioctylphosphine oxide (TOPO) and thorium toluate (Th-TA) as ionophores dispersed in poly(vinyl chloride) matrix membranes plasticized with nitrophenyloctyl ether. In strong nitric acid medium, Th(IV) nitrate is converted into [Th(NO3)6]2− complex and sensed as anionic divalent ion which exclude most cationic effect. Validation of the assay methods using the quality assurance standards (linearity range, accuracy, precision, within-day variability, between-day-repeatability, lower detection limit and sensitivity) reveals excellent performance characteristics of both sensors. The sensors exhibit near-Nernstian response for 1.0×10−6–1.0×10−1 M Th over the pH range 2.5–4.5. Calibration slopes of −32.3±0.3 and −27.2±0.2 mV/decade, precision of ±0.5 and ±0.8% and accuracy of 98.8±0.9 and 97.9±0.7% are obtained with TOPO and Th-TA based sensors, respectively. Negligible interferences are caused by most interfering mono-, di-, tri-, tetra-, penta-, and hexa-valent elements commonly associated with thorium in naturally occurring minerals and ores. High concentrations of Cl−, F−, SO42−, and NO3− ions have no diverse effect. Complete removal of the effect of the interferents in complex matrices is achieved by retention of [Th(NO3)6]2− complex from 5 M nitric acid/methanol mixture (1 : 9 v/v) on a strong anion exchanger, washing out the cationic interferents followed by stripping off thorium anion complex and measurements. Both sensors are used for determining thorium in certified thorium ore samples (20–120 mg Th/kg) and some naturally occurring ores (200–600 mg Th/kg). The results obtained agree fairly well with the certified labeled values or the data obtained using X-ray fluorescence spectrometry |
اللغة | en |
الناشر | Wiley-VCH Verlag |
الموضوع | Anionic response Poly(vinyl chloride) membranes Potentiometry Thorium hexanitrate anion Thorium ores Thorium sensors Thorium toluate Trioctylphosphine oxide (TOPO) |
النوع | Article |
الصفحات | 2063-2069 |
رقم العدد | 19 |
رقم المجلد | 20 |
الملفات في هذه التسجيلة
الملفات | الحجم | الصيغة | العرض |
---|---|---|---|
لا توجد ملفات لها صلة بهذه التسجيلة. |
هذه التسجيلة تظهر في المجموعات التالية
-
الكيمياء وعلوم الأرض [587 items ]