عرض بسيط للتسجيلة

المؤلفPrajapati, Pintu
المؤلفDhameliya, Rutvik
المؤلفJha, Rahul
المؤلفShah, Pranav
المؤلفPulusu, Veera Shakar
المؤلفHaque, Anzarul
المؤلفAhmad, Sarfaraz
المؤلفShah, Shailesh
تاريخ الإتاحة2024-09-11T04:40:15Z
تاريخ النشر2024-01-01
اسم المنشورChemistry Africa
المعرّفhttp://dx.doi.org/10.1007/s42250-024-01007-z
الاقتباسPrajapati, P., Dhameliya, R., Jha, R. et al. In-Vitro Dissolution Study of Solid Dispersion Adsorbate of Nateglinide by Eco-Friendly Liquid Chromatography-Tandem Mass Spectrometric Method through Harmonized Approach of White Analytical Chemistry and Analytical Quality by Design. Chemistry Africa (2024). https://doi.org/10.1007/s42250-024-01007-z
الرقم المعياري الدولي للكتاب25225758
معرّف المصادر الموحدhttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85196303418&origin=inward
معرّف المصادر الموحدhttp://hdl.handle.net/10576/58774
الملخصPurpose: Nateglinide, a member of the meglitinide class, is used as an oral antihyperglycemic agent to treat non-insulin-dependent diabetes mellitus. It falls under the BCS class II category and has a low solubility (0.00848 mg/mL), posing challenges in its formulation. To overcome this, a solid dispersion adsorbate of nateglinide was prepared using the fusion method applying 32 factorial experimental design. There are several analytical techniques for quantifying nateglinide in pharmaceutical formulations and biological fluids, but many depend on toxic organic solvents in their mobile phases, which can be harmful to the environment. Methods: To address this issue, a green liquid chromatographic-tandem mass spectrometric method was developed. This method, used for assessing the in-vitro dissolution study of the solid dispersion adsorbate of nateglinide, employs low toxic organic solvents. The method development adhered to the principles of analytical quality by design to minimize the generation of organic waste. Results: The chromatographic analysis was conducted using a C8 column (50 mm × 2.1 mm, 1.7 μm) with 20.0 mmol/L ammonium acetate and ethanol (75:25, v/v) as the mobile phase. Conclusions: In conclusion, this analytical approach not only ensures accurate analysis of nateglinide but also promotes sustainability by reducing environmental impact.
اللغةen
الناشرSpringer Nature
الموضوعAnalytical Quality by Design
Liquid chromatography-tandem mass Spectrometric Method
Nateglinide
Solid Dispersion Adsorbate
White Analytical Chemistry
العنوانIn-Vitro Dissolution Study of Solid Dispersion Adsorbate of Nateglinide by Eco-Friendly Liquid Chromatography-Tandem Mass Spectrometric Method through Harmonized Approach of White Analytical Chemistry and Analytical Quality by Design
النوعArticle
ESSN2522-5766
dc.accessType Full Text


الملفات في هذه التسجيلة

Thumbnail

هذه التسجيلة تظهر في المجموعات التالية

عرض بسيط للتسجيلة