    Experimental investigation of double-pipe heat exchangers in air conditioning applications

    Thumbnail
    View/Open
    Publisher version (You have accessOpen AccessIcon)
    Publisher version (Check access options)
    Check access options
    1-s2.0-S0378778817311866-main.pdf (2.978Mb)
    Date
    2018
    Author
    Ghani, Saud
    Gamaledin, Seifelislam Mahmoud Ahmad
    Rashwan, Mohammed Mohammed
    Atieh, Muataz Ali
    Metadata
    Show full item record
    Abstract
    The increased demand of energy in domestic applications necessitates the development of innovative engineering solutions in building heating, ventilating, and air conditioning (HVAC) systems. As the largest energy intensive sector is domestic buildings, more focus is currently directed to reduce air conditioning energy consumption. Double-pipe heat exchangers are considered one of the practical solutions in today's HVAC industry. Nevertheless, a few studies focus on using double-pipe heat exchangers in air conditioning applications. This paper experimentally investigates the usage of double-pipe condenser and evaporator in an air conditioning system serving a 45 m3 balanced calorimeter of 2.24 kW heat load. Deionized water (DIW) was used as the secondary heat transfer working fluid for both the evaporator and condenser units, and R-22 was used as the AC system refrigerant. Experimental results of the double-pipe heat evaporator/condenser setup showed a promising reduction in the compressor work and an increase in the system coefficient of performance (COP). The collected data showed that the system efficiency depends more on the evaporator DIW flowrate than on the condenser DIW flowrate. By increasing the DIW flowrate in the evaporator, the compressor work was shown to decrease, while the COP was shown to increase. In comparison with a standard rated air conditioning unit, using a double-pipe evaporator and condenser units with the maximum DIW flowrates resulted in a decrease of about 53% in the compressor work and a similar percentage of increase in the system COP.
    DOI/handle
    http://dx.doi.org/10.1016/j.enbuild.2017.10.051
    http://hdl.handle.net/10576/61236
    Collections
    • Mechanical & Industrial Engineering [‎1483‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video