Available date2025-07-01T07:43:50Z
Publication Date2024-01-05
Publication NameApplied Thermal Engineering
Identifierhttp://dx.doi.org/10.1016/j.applthermaleng.2023.121536
CitationWang, S., Wei, W., Xie, J., Wang, W., Sun, Y., Li, Z., ... & Deng, S. (2024). Space heating performance analysis of air source heat pump integrated with image gray recognition-based defrosting controller. Applied Thermal Engineering, 236, 121536.
ISSN13594311
URIhttps://www.sciencedirect.com/science/article/pii/S135943112301565X
URIhttp://hdl.handle.net/10576/65925
AbstractIn practice, owing to the unreasonable defrosting initiating method of air source heat pumps (ASHPs), mal–defrost occurs frequently, further leading to the increase of building heating energy consumption. In recent years, with the development of image recognition technology in many fields, it has been expected to be used in defrosting initiating control methods of ASHPs. Although former investigations demonstrate that it is feasible and promising, there is still lack of a control strategy to make it become reality. To promote the application of image recognition in defrosting initiating method of ASHPs, a control strategy for the defrosting initiating method based on image gray recognition was proposed in the present work and used in an image gray recognition equipment (IGRE). Then, nine groups of experiments were conducted based on this new IGRE method. Results indicate that the proposed control strategy for the IGRE method is feasible and practical. By employing this new IGRE method, the defrosting accuracy rate and the average COP of the ASHPs are respectively 42.86% and 36.60% higher, compared with those using the conventional T–T method. In complex and variable environments, the defrosting accuracy rate of this new IGRE method reaches 93.33% in a 10–day test.
SponsorThis work was supported partially by the Beijing natural fund & municipal education commission co–sponsored project (Grant No. KZ202010005003).
Languageen
PublisherElsevier
SubjectAir source heat pumps
Defrosting initiating control
Image recognition
Building heating energy consumption
Defrosting accuracy rate
TitleSpace heating performance analysis of air source heat pump integrated with image gray recognition-based defrosting controller
TypeArticle
Issue NumberPart B
Volume Number236
ESSN1873-5606