المؤلفShiquan, Wang
المؤلفWei, Wenzhe
المؤلفLuo, Jianfei
المؤلفWang, Wei
المؤلفSun, Yuying
المؤلفLi, Zhaoyang
المؤلفHuang, Chengyang
المؤلفTang, Rui
المؤلفDeng, Shiming
تاريخ الإتاحة2025-07-01T07:59:48Z
تاريخ النشر2025-01-01
اسم المنشورEnergy and Buildings
المعرّفhttp://dx.doi.org/10.1016/j.enbuild.2024.115079
الاقتباسWang, S., Wei, W., Luo, J., Wang, W., Sun, Y., Li, Z., ... & Deng, S. (2025). A prediction model of the optimal defrosting initiating time for the air source heat pumps with different configurations and operations. Energy and Buildings, 326, 115079.
الرقم المعياري الدولي للكتاب03787788
معرّف المصادر الموحدhttps://www.sciencedirect.com/science/article/pii/S0378778824011952
معرّف المصادر الموحدhttp://hdl.handle.net/10576/65929
الملخصFrosting is a critical challenge that affects the energy efficiency of air source heat pumps (ASHPs). Defrosting periodically is the most widely used method to solve this problem. However, the rate of frosting varies considerably for ASHPs due to their configurations and operations (CICO) being different. This leads to the obvious differences in their defrosting initiating time. Defrosting too early or too late will both cause energy loss. To ensure the efficient operation of ASHPs, the variations of energy loss coefficient caused by frosting-defrosting (εNL) and the defrosting initiating time for ASHPs with different CICO values were investigated. Based on the theory of optimal defrosting initiating time (Topt) and experimental results under different frosting durations, the Topt for different ASHPs is found. Then, a prediction model for ASHPs with different CICO values is established. Results show that there is a Topt for ASHPs with different CICO values, respectively. Under the frosting condition of 2/1 ℃, the Topt increases with the rise of CICO values. When the CICO values increase from 3.14 to 22.44, the corresponding Topt increases from 22 min to 148 min. By fitting the Topt and CICO values, a cubic mathematical model for the prediction of the optimal defrosting time of ASHPs has been developed.
راعي المشروعThis work was supported by the General Program of the National Natural Science Foundation of China (Grant No. 52378086).
اللغةen
الناشرElsevier
الموضوعAir source heat pumps
Optimal defrosting initiating time
Different configurations and operations
Frosting energy loss
Defrosting energy loss
العنوانA prediction model of the optimal defrosting initiating time for the air source heat pumps with different configurations and operations
النوعArticle