عرض بسيط للتسجيلة

المؤلفXiaoxia, Bai
المؤلفLiu, Shengnan
المؤلفDeng, Shiming
المؤلفZhang, Long
المؤلفWei, Minchen
تاريخ الإتاحة2025-07-01T08:33:42Z
تاريخ النشر2023-03-05
اسم المنشورApplied Thermal Engineering
المعرّفhttp://dx.doi.org/10.1016/j.applthermaleng.2022.119933
الاقتباسBai, X., Liu, S., Deng, S., Zhang, L., & Wei, M. (2023). A modelling study on the frosting characteristics of a novel dual-fan outdoor coil in an Air Source Heat Pump unit. Applied Thermal Engineering, 222, 119933.
الرقم المعياري الدولي للكتاب13594311
معرّف المصادر الموحدhttps://www.sciencedirect.com/science/article/pii/S1359431122018634
معرّف المصادر الموحدhttp://hdl.handle.net/10576/65930
الملخصUneven frosting along the airflow direction in a traditional outdoor coil in air source heat pumps (ASHPs) was inevitable due to a fixed one-way outdoor airflow direction, causing a rapid deterioration in heating performances of ASHPs. To alleviate this uneven frosting phenomenon, a novel dual-fan outdoor coil where air flow direction can be alternately reversed was proposed in a previous experimental study. To more effectively and comprehensively study the operating characteristics of ASHPs having the dual-fan outdoor coil at different fan operating modes, with different configurations and under different operating ambient conditions, a dynamic mathematical model for the experimental ASHP having the dual-fan outdoor coil was developed and experimentally validated. Then a follow-up modelling study for different operating modes of the two fans, fin pitches and operating ambient conditions was carried out using the validated model. The modelling results demonstrated that by optimizing fan operating mode, the difference in frost thickness between the windward and leeward sides of the dual-fan outdoor coil can be reduced by up to 77.3 %, the averaged output heating capacity and COP improved by up to 11.1 % and 12.7 %, respectively, and the number of switching operation of the two fans decreased by 55.6 %. Besides, the recommendations for using the dual-fan outdoor coil at different operating modes of the two fans, different fin pitches and operating ambient conditions were also made. The model can be used as a useful tool in helping achieve higher operating efficiency for ASHPs having the novel dual-fan outdoor coil.
راعي المشروعThe authors acknowledge the financial supports from the Hong Kong Polytechnic University.
اللغةen
الناشرElsevier
الموضوعAir source heat pump
Novel dual-fan outdoor coil
Dynamic mathematical model
Even frosting characteristics
Heating performances
العنوانA modelling study on the frosting characteristics of a novel dual-fan outdoor coil in an Air Source Heat Pump unit