    Comparative power demand of mechanical and aeration imposed shear in an immersed membrane bioreactor

    Thumbnail
    View/Open
    Publisher version (You have accessOpen AccessIcon)
    Publisher version (Check access options)
    Check access options
    1-s2.0-S0043135417307790-main.pdf (1.460Mb)
    Date
    2017-12-01
    Author
    Buzatu, P.
    Qiblawey, H.
    Nasser, M.S.
    Judd, S.
    Metadata
    Show full item record
    Abstract
    The power demanded for the application of mechanically-imposed shear on an immersed flat sheet (iFS) membrane bioreactor (MBR) has been compared to that of conventional membrane air scouring. Literature correlations based on the Ostwald model were used to define the rheological characteristics of an MBR sludge. The correlation of specific power demand (P'¯, in Watts per m2 membrane area) with shear rate γ in s−1 was developed from first principles through a consideration of the force balance on the system in the case of mechanically-imposed shear. The corresponding aeration imposed shear correlation was interpreted from literature information.The analysis revealed the energy required to impose a shear mechanically through oscillation (or reciprocation) of the membrane to be between 20 and 70% less than that demanded for providing the same shear by conventional aeration of the immersed membrane. The energy saving increases with decreasing shear in accordance with a power demand ratio (aeration:mechanical) of 1400γ−1.4 for a specific sludge rheology. Whilst the absolute P'¯ value is dependent on the sludge rheology, the aeration:mechanical power demand ratio is determined by the difference in the two exponents in the respective correlations between P'¯ and γ. Consequently, aeration-imparted shear becomes energetically favoured beyond some threshold shear rate value (∼180 s−1, based on the boundary conditions applied in the current study). The outcomes qualitatively corroborate findings from the limited practical measurement of energy demand in MBRs fitted with reciprocating immersed membranes.
    URI
    https://www.sciencedirect.com/science/article/pii/S0043135417307790
    DOI/handle
    http://dx.doi.org/10.1016/j.watres.2017.09.024
    http://hdl.handle.net/10576/69370
    Collections
    • Chemical Engineering [‎1312‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us
    Contact Us | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policies

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us
    Contact Us | QU

     

     

    Video