عرض بسيط للتسجيلة

المؤلفKhan A.
المؤلفBen-Brahim L.
المؤلفGastli A.
المؤلفAl-Emadi N.
تاريخ الإتاحة2019-09-24T07:47:38Z
تاريخ النشر2018
اسم المنشورProceedings - 2018 IEEE 12th International Conference on Compatibility, Power Electronics and Power Engineering, CPE-POWERENG 2018
اسم المنشور12th IEEE International Conference on Compatibility, Power Electronics and Power Engineering, CPE-POWERENG 2018
المصدرScopus
الترقيم الدولي الموحد للكتاب 9.78E+12
معرّف المصادر الموحدhttp://dx.doi.org/10.1109/CPE.2018.8372513
معرّف المصادر الموحدhttp://hdl.handle.net/10576/11904
الملخصThe shoot-through problem of conventional H-Bridge inverters imposes a threat to system's reliability and efficiency. This is because the unintentional shoot-through state short-circuits the DC-Link capacitor. To overcome the severity of the shoot-through state, Dual Buck Inverters (DBIs) were introduced. These topologies have at least one inductor connected in-parallel with the DC-Link capacitor at accidental shoot-through states' activation; thus, preventing the DC-side from getting short-circuited. Besides, DBIs' circulate inherently low ground leakage current and thereby they are considered as attractive choices in single-phase non-isolated grid-connected Photovoltaic (PV) applications. Therefore, this work proposes a modified non-isolated grid-tied LCL-filter based DBI with a control scheme that improves the reliability and the stability. Specifically, adopting an appropriate Active Power Decoupling Control (APDC) scheme enhances the reliability. This scheme utilizes the Common-Mode (CM) operation of the DBI. As for stability assurance, an Active Resonance Damping Control (ARDC) is developed. This ARDC is deployed in both inverter modes, the CM and the Differential-Mode (DM). Eventually, the theoretical analyses are confirmed on a 3 kW / 30 ?? electrolytic capacitor-less system. The results showed that the single-phase low frequency ripples of the DC-bus voltage were negligible. Meaning that, the input capacitance requirement of the system is reduced about 40-50 times compared to the conventional methodology. Consequently, utilizing reliable polypropylene film capacitors for effective DC-Linking.
اللغةen
الناشرInstitute of Electrical and Electronics Engineers Inc.
الموضوعActive Power Decoupling Control (APDC)
Active Resonance Damping Control (ARDC)
Dual Buck Inverter (DBI)
Grid-Connected
Non-isolated
Photovoltaic (PV)
العنوانElectrolytic capacitor-less dual buck inverter with CM and DM active resonance damping control for Non-isolated grid-connected PV applications