• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Civil and Environmental Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Civil and Environmental Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Pull-off characterization of FRCM/Concrete interface

    Thumbnail
    View/Open
    Publisher version (You have accessOpen AccessIcon)
    Publisher version (Check access options)
    Check access options
    Date
    2019
    Author
    Ebead U.
    Younis A.
    Metadata
    Show full item record
    Abstract
    Fabric-reinforced cementitious matrix (FRCM) composites are usually surface-applied for strengthening reinforced concrete (RC) structures. The efficacy of the FRCM strengthening systems is dependent on the FRCM/concrete bond performance. This paper reports on the experimental results of FRCM/concrete bond characterization through pull-off tests. Six FRCM-strengthened RC slabs ( mm) were prepared and enabled conducting 72 FRCM/concrete pull-off tests. The parameters investigated included: (a) FRCM material (carbon or polyparaphenylene benzobisoxazole (PBO)); (b) level of substrate roughness (no/low/high roughening); and (c) specimen's test age (7, 28, 56, and 84 days). All FRCM systems were single-plied. The study revealed a significance of the surface preparation and test age of specimens on the FRCM/concrete pull-off strength. High-roughness specimens showed an average of 74% pull-off strength increase compared to those without roughening. Also, specimens tested at Day 84 showed 54% strength increase compared to those tested at Day 7, on average. PBO-FRCM system showed slightly higher pull-off strength than that of the carbon counterpart. The specimens showed two distinctive failure types at the (i) fabric/mortar interface and (ii) concrete/matrix interface: the latter was more prominent in carbon-FRCM. Nonetheless, the failure mode was most dependent on the fabric geometry and the substrate roughness. Based on a statistical analysis of the tested specimens, prediction models were proposed for the FRCM/concrete pull-off strength and failure mode.
    DOI/handle
    http://dx.doi.org/10.1016/j.compositesb.2019.02.025
    http://hdl.handle.net/10576/13461
    Collections
    • Civil and Environmental Engineering [‎862‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video