    Concurrent validity and within-session reliability of gait kinematics measured using an inertial motion capture system with repeated calibration

    Thumbnail
    View/Open
    Publisher version (You have accessOpen AccessIcon)
    Publisher version (Check access options)
    Check access options
    Berner et al 2020.pdf (1.679Mb)
    Date
    2020-10-31
    Author
    Karina, Berner
    Cockcroft, John
    Morris, Linzette D.
    Louw, Quinette
    Metadata
    Show full item record
    Abstract
    IntroductionWearable inertial measurement units (IMUs) enable gait analysis in the clinic, but require calibrations that may affect subsequent gait measurements. This study assessed concurrent validity and within-session reliability of gait kinematics measured by a frequently calibrated IMU-based system. Calibration pose accuracy and intra-rater repeatability, and IMU orientation tracking accuracy, were additionally quantified. MethodsCalibration poses and gait were recorded in 15 women using IMUs and optical motion capture (OMC) (reference standard) simultaneously. Participants performed six consecutive trials: each comprising a calibration pose and a walk. IMU tracking was assessed separately (once-off) using technical static and dynamic tests. Differences of > 5° constituted clinical significance. ResultsConcurrent validity for gait revealed clinically significant between-system differences for sagittal angles (root-mean-square error [RMSE] 6.7°–15.0°; bias −9.3°–3.0°) and hip rotation (RMSE 7.9°; bias −4.2°). After removing modelling offsets, differences for all angles (except hip rotation) were < 5°. Gait curves correlated highly between systems (r > 0.8), except hip rotation, pelvic tilt and -obliquity. Within-session reliability of IMU-measured gait angles was clinically acceptable (standard error of measurement [SEM] < 5°). Calibration poses were repeatable (SEM 0.3°–2.2°). Pose accuracy revealed mean absolute differences (MAD) < 5° for all angles except sagittal ankle, hip and pelvis. IMU tracking accuracy demonstrated RMSE ≤ 2.0°. ConclusionA frequently calibrated IMU system provides reliable gait measurements; comparing highly to OMC after removing modelling differences. Calibration poses can be implemented accurately for most angles and consistently. IMU-measured gait data are clinically useful and comparable within participants, but should not be compared to OMC-measured data.
    URI
    https://www.sciencedirect.com/science/article/pii/S1360859220300875
    DOI/handle
    http://dx.doi.org/10.1016/j.jbmt.2020.06.008
    http://hdl.handle.net/10576/16454
    Collections
    • Physical Therapy & Rehabilitation [‎81‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video