• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Civil and Environmental Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Civil and Environmental Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Numerical parametric investigation on the moment redistribution of basalt FRC continuous beams with basalt FRP bars

    Thumbnail
    View/Open
    Publisher version (You have accessOpen AccessIcon)
    Publisher version (Check access options)
    Check access options
    Numerical parametric investigation on the moment redistribution of basalt FRC continuous beams with basalt FRP bars.pdf (4.307Mb)
    Date
    2021-12
    Author
    Abushanab, Abdelrahman
    Alnahhal, Wael
    Metadata
    Show full item record
    Abstract
    Recently, researchers’ efforts have been directed toward using fiber-reinforced concrete (FRC) in lieu of conventional concrete to improve the compressive strain, tensile strength capacity, cracking patterns, and ductility of fiber-reinforced polymer (FRP) reinforced concrete members. In this study, a numerical one-factor-at-a-time parametric study including 144 finite element (FE) models was performed using ABAQUS 6.14 software to deeply explore the influence of the volume ratios of basalt macro-fiber (BMF), reinforcement ratios of basalt FRP (BFRP) bars, and stirrups spacing on the moment redistribution of basalt FRC continuous beams reinforced with BFRP bars. It was shown that the most influential parameter on the moment redistribution was the longitudinal reinforcement configuration. While a higher moment redistribution was noticed with higher sagging reinforcement ratios and BMF, stirrups spacing showed no effect on the moment redistribution. It was also observed that the moments were inversely distributed for FE models having high hogging-to-sagging reinforcement ratios. The sagging-to-hogging reinforcement ratio is recommended to be at least 1.6 to ensure a uniform moment redistribution. Furthermore, a multiple linear regression model was developed using Minitab 17 software to establish a relationship between the investigated parameters and the beams’ moment redistribution. The moment redistribution was accurately predicted using the developed regression model.
    DOI/handle
    http://dx.doi.org/10.1016/j.compstruct.2021.114618
    http://hdl.handle.net/10576/24617
    Collections
    • Civil and Environmental Engineering [‎862‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video