Calibration & Temperature Controlled Setup for Air Quality Sensors
Abstract
Indoor air pollution is a major issue affecting public health. Due to hot climate, humidity and lack of natural green spaces, life is mostly confined indoors in many countries of the MENA region. Vulnerable population, including young children and senior citizens who spend most of their time indoors, are at risk because of the effects of indoor air quality (IAQ) on their health. An indoor air quality monitoring system is a need of the hour to detect and improve Indoor Air Quality (IAQ). The monitoring systems presently available are bulky, expensive and need periodic calibration to maintain high degree of accuracy. Frequent recalibration of a number of densely deployed individual sensors in the network is a time-consuming and laborious task therefore self-calibration is indispensable. Gas sensors, even if factory-calibrated, tend to drift with time/usage. Therefore these should be regularly calibrated under controlled environments. Calibration may be carried out using test gas mixtures with known composition. Pre-mixed gas cylinders with known composition may be used for the purpose; however this solution is not flexible as the number of calibration points and testing conditions (e.g. effect of temperature and humidity on CO2 sensor) are limited. In the current project, a computer-controlled test and calibration test bed system is being designed and assembled along with temperature controller. Calibration set-up would help in self calibration of the air quality sensors. Calibration curves obtained from proposed calibration test bed are updated automatically and fed into the sensor node through wireless communication without going in the field or replacing the sensor. A computer-controlled test and calibration test bed system is designed and assembled containing the sensor(s) under test and in which gas composition; temperature can be precisely and dynamically controlled. ATMEGA328 micro controller is used to receive the temperature set point from the computer running the test rig.
DOI/handle
http://hdl.handle.net/10576/31487Collections
- Computer Science & Engineering [2402 items ]