عرض بسيط للتسجيلة

المؤلفRem, Jalab
المؤلفAwad, Abdelrahman M.
المؤلفNasser, Mustafa S.
المؤلفMinier-Matar, Joel
المؤلفAdham, Samer
تاريخ الإتاحة2022-09-12T06:28:31Z
تاريخ النشر2020-12-31
اسم المنشورJournal of Environmental Chemical Engineering
المعرّفhttp://dx.doi.org/10.1016/j.jece.2020.104494
الاقتباسJalab, R., Awad, A. M., Nasser, M. S., Minier-Matar, J., & Adham, S. (2020). Pilot-scale investigation of flowrate and temperature influence on the performance of hollow fiber forward osmosis membrane in osmotic concentration process. Journal of Environmental Chemical Engineering, 8(6), 104494.‏
الرقم المعياري الدولي للكتاب22133437
معرّف المصادر الموحدhttps://www.sciencedirect.com/science/article/pii/S2213343720308435
معرّف المصادر الموحدhttp://hdl.handle.net/10576/33857
الملخصForward osmosis (FO) relying on the osmotic pressure difference across semi-permeable membrane draws permeate by the effect of saline draw solution (DS) turning diluted and leaving the feed solution (FS) concentrated. However, the energy intensive step of DS recovery makes FO a challenging process. The energy benefit of FO emerges when recovery step is obviated and FO is applied as an osmotic concentration (OC) process. OC implementations for volume reduction are still at bench-scale and the investigation at larger scale is among the breakthroughs. In this paper, the performance of hollow fiber (HF) membrane in pilot-scale OC process for reducing volume of feed was investigated. The impact of operating conditions such as flowrates and temperature was evaluated. FS and DS flowrates of 1.35 and 0.35 L.min-1 respectively are optimum conditions with 75% feed recovery and 1.90 LMH water flux. Reverse solute flux increased at higher flowrates. Results indicated the role of high DS flowrate and temperature in improving the performance. DS flowrate of 0.35 L.min-1 at constant FS flow of 1.10 L.min-1 and 27 °C was most suitable for achieving 84.5% feed recovery and 1.82 LMH water flux. Above all, the long-term performance of OC pilot-plant was demonstrated through 48 h of continuous operation where stable flux trend at an average water flux of 1.66 LMH was successfully achieved. Lastly, the permeability coefficients of HF membrane were enhanced at higher temperature.
اللغةen
الناشرElsevier Ltd
الموضوعForward osmosis
Pilot-scale
Osmotic concentration (OC)
Hollow fiber (HF) membrane
Operating conditions
العنوانPilot-scale investigation of flowrate and temperature influence on the performance of hollow fiber forward osmosis membrane in osmotic concentration process
النوعArticle
رقم العدد6
رقم المجلد8
Open Access user License http://creativecommons.org/licenses/by/4.0/


الملفات في هذه التسجيلة

Thumbnail

هذه التسجيلة تظهر في المجموعات التالية

عرض بسيط للتسجيلة