Show simple item record

AuthorPrasad, S. J.Suji
AuthorIndra, J.
AuthorThangatamilan, M.
AuthorMeena, Radhey Shyam
AuthorMuthusamy, Suresh
AuthorPanchal, Hitesh
AuthorKrishnamoorthy, Mahendran
AuthorSadasivuni, Kishor Kumar
AuthorDoshi, Manish
Available date2023-05-17T09:43:45Z
Publication Date2022-07-19
Publication NameSmart and Sustainable Manufacturing Systems
Identifierhttp://dx.doi.org/10.1520/SSMS20210019
ISSN2520-6478
URIhttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85137149840&origin=inward
URIhttp://hdl.handle.net/10576/42848
AbstractPressure gauge calibration refers to comparing the standard and test gauge to determine the error percentage. The reading accuracy of the analog dial pressure gauge is found in the conventional method through manual calculations and then tabulating the values in the calibration certificate. The present study is undertaken to increase the accuracy level of the analog dial pressure gauges. A new automated computer-based method is proposed to calibrate the meters more accurately than the conventional method. The indicated value of the pressure gauge is obtained through the angular position of the pointer and the error value is identified by comparing both standard and test gauge values. In this work, Red, Green, Blue (RGB) images of standard and test pressure gauges are acquired through a high-definition camera. After the image processing operations, the pointer orientation of the indicatoris identified, and the indicated values are calculated. The computer-vision-based automatic calibration system is applied in a 0–100-psi (0–689.476 kPa) analog dial pressure gauge, and three trials were performed to determine the accuracy. The computer vision technique improved accuracy, varying from 97 % to 98 % compared with the conventional manual observation method. The observed results have improved repeatability and accuracy with the proposed computer-vision-based system.
Languageen
PublisherAmerican Society for Testing and Materials
SubjectAdaptive thresholding
Calibration
Computer vision technique
Image processing
LabVIEW
Morphological operations
Pressure gauge
Region of interest
TitleDesign and development of novel computer vision-based automatic calibration system for analog dial pressure gauge
TypeArticle
Issue Number1
Volume Number6
ESSN2572-3928


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record