عرض بسيط للتسجيلة

المؤلفElgenedy, M.A.
المؤلفAbdel-Khalik, A.S.
المؤلفElserougi, A.
المؤلفAhmed, Shehab
المؤلفMassoud, A.
تاريخ الإتاحة2016-06-22T12:15:26Z
تاريخ النشر2014
اسم المنشور7th IET International Conference on Power Electronics, Machines and Drives (PEMD 2014)
المعرّفhttp://dx.doi.org/10.1049/cp.2014.0329
الاقتباسM. A. Elgenedy, A. S. Abdel-Khalik, A. Elserougi, S. Ahmed and A. Massoud, "Fault-tolerant control of five-phase current source inverter for medium-voltage drives," Power Electronics, Machines and Drives (PEMD 2014), 7th IET International Conference on, Manchester, 2014, pp. 1-6.
الترقيم الدولي الموحد للكتاب 978-1-84919-815-8
معرّف المصادر الموحدhttp://hdl.handle.net/10576/4642
الملخصMultiphase Machines offer a promising solution to many practical challenges due to their advantages over the three phase counterparts, as fault-tolerant capability and lower torque ripple magnitude. Among different multiphase machines, five-phase machines correspond to a relatively practical selection in industrial applications. Multiphase machines are conventionally fed from voltage source inverter (VSI) as it facilities the operation under open-phase condition but with a sophisticated controller. Among different power converter topologies, current source inverter (CSI) features a simple inverter structure, a lower switching dv/dt, and a reliable short circuit protection. However, the control of multiphase CSI under open phase has not been yet considered in the literature. Additionally, the space vector PWM (SVPWM) of multiphase CSI is still challenging. Alternatively, the mapped sinusoidal PWM can offer simpler control over SVPWM. In this paper, a fault-tolerant controller for a five-phase CSI inverter is introduced and proposed for medium voltage drive applications. The proposed gating signal generator provides a controllable linear modulation index with the availability of over modulation. To verify the proposed fault-tolerant gating signal generator, a five-phase CSI feeds a static R-L load is simulated using MATLAB/SIMULINK as a case study exploring the healthy and the opened-phase cases.
راعي المشروعNPRP grant # [4-941-2-356] from the Qatar National Research Fund (a member of Qatar Foundation).
اللغةen
الناشرInstitution of Engineering and Technology
السلسلةIET Conference Publications
الموضوعFault tolerant control
motor drives
signal generators
torque
current source inverter
mapping circuit
multiphase machine
sinusoidal pulse width modulation
space vector pulse width modulation
العنوانFault-tolerant control of five-phase current source inverter for medium-voltage drives
النوعConference
رقم العدد628 CP
dc.accessType Abstract Only