Fault-tolerant control of five-phase current source inverter for medium-voltage drives
المؤلف | Elgenedy, M.A. |
المؤلف | Abdel-Khalik, A.S. |
المؤلف | Elserougi, A. |
المؤلف | Ahmed, Shehab |
المؤلف | Massoud, A. |
تاريخ الإتاحة | 2016-06-22T12:15:26Z |
تاريخ النشر | 2014 |
اسم المنشور | 7th IET International Conference on Power Electronics, Machines and Drives (PEMD 2014) |
المعرّف | http://dx.doi.org/10.1049/cp.2014.0329 |
الاقتباس | M. A. Elgenedy, A. S. Abdel-Khalik, A. Elserougi, S. Ahmed and A. Massoud, "Fault-tolerant control of five-phase current source inverter for medium-voltage drives," Power Electronics, Machines and Drives (PEMD 2014), 7th IET International Conference on, Manchester, 2014, pp. 1-6. |
الترقيم الدولي الموحد للكتاب | 978-1-84919-815-8 |
الملخص | Multiphase Machines offer a promising solution to many practical challenges due to their advantages over the three phase counterparts, as fault-tolerant capability and lower torque ripple magnitude. Among different multiphase machines, five-phase machines correspond to a relatively practical selection in industrial applications. Multiphase machines are conventionally fed from voltage source inverter (VSI) as it facilities the operation under open-phase condition but with a sophisticated controller. Among different power converter topologies, current source inverter (CSI) features a simple inverter structure, a lower switching dv/dt, and a reliable short circuit protection. However, the control of multiphase CSI under open phase has not been yet considered in the literature. Additionally, the space vector PWM (SVPWM) of multiphase CSI is still challenging. Alternatively, the mapped sinusoidal PWM can offer simpler control over SVPWM. In this paper, a fault-tolerant controller for a five-phase CSI inverter is introduced and proposed for medium voltage drive applications. The proposed gating signal generator provides a controllable linear modulation index with the availability of over modulation. To verify the proposed fault-tolerant gating signal generator, a five-phase CSI feeds a static R-L load is simulated using MATLAB/SIMULINK as a case study exploring the healthy and the opened-phase cases. |
راعي المشروع | NPRP grant # [4-941-2-356] from the Qatar National Research Fund (a member of Qatar Foundation). |
اللغة | en |
الناشر | Institution of Engineering and Technology |
السلسلة | IET Conference Publications |
الموضوع | Fault tolerant control motor drives signal generators torque current source inverter mapping circuit multiphase machine sinusoidal pulse width modulation space vector pulse width modulation |
النوع | Conference |
رقم العدد | 628 CP |
الملفات في هذه التسجيلة
الملفات | الحجم | الصيغة | العرض |
---|---|---|---|
لا توجد ملفات لها صلة بهذه التسجيلة. |
هذه التسجيلة تظهر في المجموعات التالية
-
الهندسة الكهربائية [2685 items ]