• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Student Thesis & Dissertations
  • College of Engineering
  • Electrical Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Student Thesis & Dissertations
  • College of Engineering
  • Electrical Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    DESIGN OF REAL-TIME FUZZY LOGIC PSS BASED ON PMUs FOR DAMPING LOW FREQUENCY OSCILLATIONS

    Thumbnail
    View/Open
    Thesis-Master of Science (2.899Mb)
    Date
    2016-06
    Author
    Mahmood ur Rehman, Jamil ur Rahman
    Metadata
    Show full item record
    Abstract
    Poorly damped low frequency oscillations is one of the main problems threatening safe and stable operation of the interconnected power systems and reducing the capability of transmission the power. The generator's excitation system has been supplemented with the Power System Stabilizer (PSS) in order to improve the damping of these low oscillations. In the latest smart power grids, the Phasor Measurement Units (PMUs) become a fundamental element in the monitoring, protection and control applications as PMU signals are more accurate than the conventional measurement units and real time GPS stamped. In this study, Fuzzy Power System Stabilizer (FPSS) has been designed and its performance in damping inter-are oscillations compared with the conventional PSS (CPSS) based on the simulation with MATLAB/Simulink model. The results of the simulation with the Simulink model proved that the performance of the designed FPSS in damping inter-area oscillation is better than the CPSS. One of the main features of fuzzy controller is that it doesn't require mathematical modeling as it is designed based on the time-domain and the operator experience while, in contrast, the conventional PSS requires to be designed in the frequency domain. Real Time Digital Simulator (RTDS) has been used to develop the real-time models of the test systems. The time-domain simulations with the RTDS model when the system subjected to the large disturbance (three-phase to ground fault) have been performed to show that the designed FPSS improved the damping of the oscillations effectively. The simulation results have been verified by modal analysis.
    DOI/handle
    http://hdl.handle.net/10576/5095
    Collections
    • Electrical Engineering [‎56‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video