عرض بسيط للتسجيلة

المؤلفAl-Ammari, Wahib A.
المؤلفSleiti, Ahmad K.
تاريخ الإتاحة2024-02-11T10:55:51Z
تاريخ النشر2022-03-11
اسم المنشورEnergy Science and Engineering
المعرّفhttp://dx.doi.org/10.1002/ese3.1101
الاقتباسAl‐Ammari, W. A., & Sleiti, A. K. (2022). Comprehensive thermoeconomic, exergoeconomic, and optimization analyses of direct oxy‐combustion supercritical CO2 intercooled and reheated cycles under design and off‐design conditions. Energy Science & Engineering, 10(4), 1272-1295.
معرّف المصادر الموحدhttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85126036861&origin=inward
معرّف المصادر الموحدhttp://hdl.handle.net/10576/51762
الملخصThis study presents comprehensive energetic, exergetic, exergoeconomic, and economic (4E) performance analyses for four direct oxy-combustion (DOC) supercritical carbon dioxide (sCO2) power cycles at design, off-design, and part-load conditions. These cycles include the dual recuperator cycle (DRC), intercooling cycle (ICC), partial intercooling cycle (PIC), and reheating cycle (RHC). The analyses were conducted at relatively low turbine inlet temperatures (TIT: 550–750°C) with compressor inlet temperature (CIT) varied from 33°C (wet-cooling) to 50°C (dry-cooling). Furthermore, single- and multiobjective optimization analyses were conducted for each cycle. At design conditions (high-pressure of Pc,o = 20 MPa, low-pressure of Pc,o = 5.4 MPa, TIT = 750°C, CIT = 50°C [dry-cooling]), the PIC has the highest thermal efficiency (47.78%) compared to 38.36% for DRC, 45.71% for ICC, and 44.39% for RHC. At optimized conditions (Pc,o = 30 MPa, Pc,o = 8 MPa, TIT = 744°C, CIT = 30°C [wet-cooling]), the ICC shows superior energetic performance (52.08%) compared to 47.97% for DRC, 49.20% for PIC, and 48.62% for RHC. At off-design conditions with a power demand (PD) of 40% of the design load (50 MW), the thermal efficiency is decreased by 21.82% in DRC, 17.71% in ICC, 22.46% in PIC, and 13.60% in RHC. The ICC has the minimum levelized cost of electricity compared to the other cycles with 5.93 ¢/kWh at design conditions (dry-cooling), 5.65 ¢/kWh at optimized conditions (wet-cooling), and 7.2 ¢/kWh at minimum PD (21 MW). Therefore, from an economic point of view, the ICC is recommended as the best power block for a sCO2 power cycle driven by oxy-combustor at moderate TITs. The study also provides constructive comparisons between the DOC-sCO2 and indirect (nuclear, solar, and waste heat) sCO2 power cycle systems and the future research directions.
راعي المشروعThe work presented in this publication was made possible by NPRP‐S grant # (11S‐1231‐170155) from the Qatar National Research Fund (a member of the Qatar Foundation).
اللغةen
الناشرWiley-Blackwell
الموضوع4E analysis
design and off-design performance
direct oxy-combustion
multiobjective optimization
part-load operation
supercritical CO power cycles 2
wet and dry cooling
العنوانComprehensive thermoeconomic, exergoeconomic, and optimization analyses of direct oxy-combustion supercritical CO2 intercooled and reheated cycles under design and off-design conditions
النوعArticle
الصفحات1272-1295
رقم العدد4
رقم المجلد10
ESSN2050-0505


الملفات في هذه التسجيلة

Thumbnail

هذه التسجيلة تظهر في المجموعات التالية

عرض بسيط للتسجيلة