• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Civil and Environmental Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Civil and Environmental Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Bond durability performance of sand-coated BFRP bars in high-strength fiber reinforced concrete

    View/Open
    Publisher version (You have accessOpen AccessIcon)
    Publisher version (Check access options)
    Check access options
    1-s2.0-S0263822323006529-main.pdf (15.03Mb)
    Date
    2023
    Author
    Al-Hamrani, Abathar
    Alnahhal, Wael
    Metadata
    Show full item record
    Abstract
    The ever-increasing utilization of fiber-reinforced polymer (FRP) bars has led to a surge in research regarding their bonding properties with concrete. In this study, the bond durability behavior between high-strength fiber-reinforced concrete (FRC) and sand-coated basalt FRP (BFRP) bars was examined under three different environmental conditions including immersion in seawater solution at 50 °C for 3, 6, and 9 months, immersion in the sulfuric acid solution for 3, 6, and 9 months with an ambient temperature range of 20 to 30 °C, and exposure to 270 freeze–thaw cycles. A total of 60 pull-out samples were prepared using either basalt (B) fibers or polypropylene (PP) fibers. Plain concrete pull-out samples were served as controls. Test results revealed that all exposures have degraded the bond, leading to pull-out failure in all of the specimens. Exposure to 50 °C seawater was found to cause the most significant degradation. However, the use of basalt fibers helped to mitigate the loss of bond strength in the specimens when compared to plain concrete specimens. For example, after 3, 6, and 9 months of exposure to 50 °C seawater, bond strength retentions of 73.58%, 56.04%, and 34.47% were observed for basalt FRC (BFRC) specimens, compared to 39.64%, 49.37%, and 29.61% for plain concrete specimens. On the other hand, a lower retention in bond strength of 16.28% was recorded for polypropylene FRC (PPFRC) specimens at 9 months of exposure to 50 °C seawater. The bond stress-slip relationship of the tested bars was accurately predicted using two calibrated analytical models: the Eligehausen, Popov, and Bertero (BPE) model and the Cosenza, Manfredi, and Realfonzo (CMR) model. Notably, both models showed a strong correlation with the observed bond stress-slip relationships in the experiments.
    DOI/handle
    http://dx.doi.org/10.1016/j.compstruct.2023.117306
    http://hdl.handle.net/10576/57504
    Collections
    • Civil and Environmental Engineering [‎862‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video