المؤلفDehlela, Shabir
المؤلفAnjum, Arshak
المؤلفHamza, Hawa
المؤلفPadhan, Jhasketan
المؤلفAl-Ansari, Abdulla
المؤلفYaacoub, Elias
المؤلفMohammed, Amr
المؤلفNavkar, Nikhil V.
تاريخ الإتاحة2024-10-07T07:58:57Z
تاريخ النشر2023-08
اسم المنشورUltrasound in Medicine & Biology
المعرّفhttp://dx.doi.org/10.1016/j.ultrasmedbio.2023.04.017
الاقتباسShabir, D., Anjum, A., Hamza, H., Padhan, J., Al-Ansari, A., Yaacoub, E., ... & Navkar, N. V. (2023). Development and evaluation of a mixed-reality tele-ultrasound system. Ultrasound in Medicine & Biology, 49(8), 1867-1874.
الرقم المعياري الدولي للكتاب0301-5629
معرّف المصادر الموحدhttps://www.sciencedirect.com/science/article/pii/S0301562923001448
معرّف المصادر الموحدhttp://hdl.handle.net/10576/59832
الملخصObjectiveThe objective of this feasibility study was to develop and assess a tele-ultrasound system that would enable an expert sonographer (situated at the remote site) to provide real-time guidance to an operator (situated at the imaging site) using a mixed-reality environment. MethodsAn architecture along with the operational workflow of the system is designed and a prototype is developed that enables guidance in form of audiovisual cues. The visual cues comprise holograms (of the ultrasound images and ultrasound probe) and is rendered to the operator using a head-mounted display device. The position and orientation of the ultrasound probe's hologram are remotely controlled by the expert sonographer and guide the placement of a physical ultrasound probe at the imaging site. The developed prototype was evaluated for its performance on a network. In addition, a user study (with 12 participants) was conducted to assess the operator's ability to align the probe under different guidance modes. ResultsThe network performance revealed the view of the imaging site and ultrasound images were transferred to the remote site in 233 ± 42 and 158 ± 38 ms, respectively. The expert sonographer was able to transfer, to the imaging site, data related to position and orientation of the ultrasound probe's hologram in 78 ± 13 ms. The user study indicated that the audiovisual cues are sufficient for an operator to position and orient a physical probe for accurate depiction of the targeted tissue (p < 0.001). The probe's placement translational and rotational errors were 1.4 ± 0.6 mm and 5.4 ± 2.2º. ConclusionThe work illustrates the feasibility of using a mixed-reality environment for effective communication between an expert sonographer (ultrasound physician) and an operator. Further studies are required to determine its applicability in a clinical setting during tele-ultrasound.
راعي المشروعThis work was supported by National Priority Research Program (NPRP) Award NPRP12S-0119-190006 from the Qatar National Research Fund (a member of The Qatar Foundation).
اللغةen
الناشرElsevier
الموضوعTele-ultrasound
Mixed reality
Diagnostic imaging
Tele-medicine
Head-mounted display
العنوانDevelopment and Evaluation of a Mixed-Reality Tele-ultrasound System
النوعArticle
الصفحات1867-1874
رقم العدد8
رقم المجلد49
ESSN1879-291X
dc.accessType Abstract Only