• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Copyrights
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Effortless Totem-Pole Converter Control Using a Power Factor Correction Peak Current-Mode Controller

    Thumbnail
    View/Open
    sensors-24-04910.pdf (4.131Mb)
    Date
    2024-08-01
    Author
    Alsalemi, Abdulazeez
    Massoud, Ahmed
    Metadata
    Show full item record
    Abstract
    This paper expands a recently proposed peak current-mode (PCM) control method for a power factor correction (PFC) boost converter to include the totem-pole converter and solves the controller’s compatibility problem with the totem-pole converter by proposing three input current sensing methods. Using MATLAB/Simulink 2023b, simulation experiments on a 2 kW totem-pole converter utilizing the PFC PCM controller were carried out to assess the performance of the controller with the proposed sensing methods. The findings indicate that under steady-state conditions, all three proposed sensing methods performed input current shaping successfully and yielded nearly identical THD% of about 4.4% in the input current waveform. However, it is noteworthy that method 2, referred to as the memory method, exhibited a sluggish and less robust transient response in comparison to the swift and resilient responses observed with method 1 and method 3. Additionally, the third proposed method, which involves a single current sensor positioned across the input inductor, emerged as the optimal and cost-effective sensing solution. This method achieved the same desirable attributes of fast and robust control while utilizing only a single current sensor, a notable advantage over method 1, which employs two current sensors.
    URI
    https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85200750076&origin=inward
    DOI/handle
    http://dx.doi.org/10.3390/s24154910
    http://hdl.handle.net/10576/60176
    Collections
    • Electrical Engineering [‎2848‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us
    Contact Us | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us
    Contact Us | QU

     

     

    Video