Show simple item record

AuthorIshraque, Md Fatin
AuthorShezan, Sk  A
AuthorShafiullah, G. M.
AuthorMuyeen, S. M.
AuthorAlharbi, Talal
AuthorAlenezi, Ali H.
AuthorHossen, Md Delwar
Available date2024-12-17T09:45:13Z
Publication Date2024-09-01
Publication Namee-Prime - Advances in Electrical Engineering, Electronics and Energy
Identifierhttp://dx.doi.org/10.1016/j.prime.2024.100745
CitationIshraque, M. F., Shezan, S. A., Shafiullah, G. M., Muyeen, S. M., Alharbi, T., Alenezi, A. H., & Hossen, M. D. (2024). Operational assessment of solar-wind-biomass-hydro-electrolyser hybrid microgrid for load variations using model predictive deterministic algorithm and droop controllers. e-Prime-Advances in Electrical Engineering, Electronics and Energy, 9, 100745.‏
URIhttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85202959620&origin=inward
URIhttp://hdl.handle.net/10576/61948
AbstractThis study presents the operation and assessment of a solar-wind-biomass-hydro-electrolyser hybrid microgrid for different types of load variations by using a proprietary derivative-free algorithm (Model Predictive Deterministic Algorithm) and voltage IQ droop controller. The proposed hybrid microgrid integrates various renewable energy sources and an electrolyser to generate hydrogen and produce electricity. The objective is to optimize the microgrid's performance and provide reliable power supply to meet varying load demands. The proprietary derivative-free algorithm is used to determine the optimal dispatch of power from each energy source to meet the load demand while minimizing the overall cost of energy. Additionally, a voltage IQ droop and voltage Q droop controller are employed to regulate the voltage, frequency and active power of the microgrid and maintain its stability during load variations. The proposed hybrid microgrid is assessed under different load scenarios for both grid tied and isolated modes. The results demonstrate that the proposed hybrid microgrid with the derivative-free algorithm and voltage droop controllers can effectively operate and provide reliable power supply under different load variations while maintaining the power system stability of the microgrid. Further, the mutual performances of the controller are compared to find the best controller for the specific microgrid. The findings of this study can contribute to the development of efficient and reliable hybrid microgrid systems for sustainable energy production and distribution.
Languageen
PublisherElsevier Ltd
SubjectDerivative-free algorithm
Hybrid microgrid
Load variations
Model Predictive Deterministic Algorithm
Renewable energy sources
Voltage IQ droop controller
Voltage Q droop controller
TitleOperational assessment of solar-wind-biomass-hydro-electrolyser hybrid microgrid for load variations using model predictive deterministic algorithm and droop controllers
TypeArticle
Volume Number9
dc.accessType Abstract Only


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record