    Space heating performance analysis of air source heat pump integrated with image gray recognition-based defrosting controller

    View/Open
    Publisher version (You have accessOpen AccessIcon)
    Publisher version (Check access options)
    Check access options
    1-s2.0-S135943112301565X-main.pdf (5.201Mb)
    Date
    2024-01-05
    Author
    Shiquan, Wang
    Wei, Wenzhe
    Xie, Jingsi
    Wang, Wei
    Sun, Yuying
    Li, Zhaoyang
    Lin, Yao
    Huang, Chengyang
    Deng, Shiming
    ...show more authors ...show less authors
    Metadata
    Show full item record
    Abstract
    In practice, owing to the unreasonable defrosting initiating method of air source heat pumps (ASHPs), mal–defrost occurs frequently, further leading to the increase of building heating energy consumption. In recent years, with the development of image recognition technology in many fields, it has been expected to be used in defrosting initiating control methods of ASHPs. Although former investigations demonstrate that it is feasible and promising, there is still lack of a control strategy to make it become reality. To promote the application of image recognition in defrosting initiating method of ASHPs, a control strategy for the defrosting initiating method based on image gray recognition was proposed in the present work and used in an image gray recognition equipment (IGRE). Then, nine groups of experiments were conducted based on this new IGRE method. Results indicate that the proposed control strategy for the IGRE method is feasible and practical. By employing this new IGRE method, the defrosting accuracy rate and the average COP of the ASHPs are respectively 42.86% and 36.60% higher, compared with those using the conventional T–T method. In complex and variable environments, the defrosting accuracy rate of this new IGRE method reaches 93.33% in a 10–day test.
    URI
    https://www.sciencedirect.com/science/article/pii/S135943112301565X
    DOI/handle
    http://dx.doi.org/10.1016/j.applthermaleng.2023.121536
    http://hdl.handle.net/10576/65925
    Collections
    • Mechanical & Industrial Engineering [‎1499‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video