    A method for sizing air source heat pump considering the joint effect of outdoor air temperature and relative humidity

    Thumbnail
    View/Open
    Publisher version (You have accessOpen AccessIcon)
    Publisher version (Check access options)
    Check access options
    1-s2.0-S2352710222018216-main.pdf (8.860Mb)
    Date
    2023-04-15
    Author
    Zhaoyang, Li
    Wei, Wenzhe
    Wang, Wei
    Sun, Yuying
    Wang, Shiquan
    Lin, Yao
    Huang, Chengyang
    Wu, Yong
    Deng, Shiming
    ...show more authors ...show less authors
    Metadata
    Show full item record
    Abstract
    When operated in a highly humid environment, frost may accumulate on the surface of the outdoor coil in air source heat pump units (ASHPs), leading to a reduction in its output heating capacity. Currently, the existing methods for sizing ASHPs only considered the effect of outdoor air temperature, Ta, without taking into account the effect of relative humidity, RH, on output heating capacity. This often resulted in an insufficient heating capacity from an ASHP selected. To resolve this issue, a model for predicting the output heating capacity of ASHPs, Qh, was established firstly. Then, considering the variation in the rated output heating capacity of ASHPs, a method for sizing ASHPs considering the joint effect of Ta and RH has been developed. Besides, for practical application, a capacity design correction factor, K, was proposed, evaluated, and plotted as a cloud picture. Evaluating results indicated that K can be used for sizing ASHPs accurately. When the effect of frosting on Qh was considered, the maximum rates of decrease in the output heating capacity correction factor, KQ, was between 43.8% and 50.0%, and the outdoor air design temperatures for space heating in six typical Chinese cities were decreased by 1.8–3.5 °C, with the average of 2.8 °C. For highly humid cities, such as Qiannan area China, even if its outdoor air design temperature was 1.4 °C higher than that in Chongqing City, the K value was 0.24 lower.
    URI
    https://www.sciencedirect.com/science/article/pii/S2352710222018216
    DOI/handle
    http://dx.doi.org/10.1016/j.jobe.2022.105815
    http://hdl.handle.net/10576/65926
    Collections
    • Mechanical & Industrial Engineering [‎1499‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video