Search
Now showing items 1-4 of 4
An LCL filter-based grid-interfaced three-phase voltage source inverter: Performance evaluation and stability analysis
(
Institution of Engineering and Technology
, 2014 , Conference Paper)
Power converters in grid connection applications commonly employ Sinusoidal Pulse-Width Modulation (SPWM) technique. Passive filters are employed in order to attenuate the generated switching current ripples and reduces ...
Capacitor voltage balancing using redundant states of space vector modulation for five-level diode clamped inverters
(
IEEE
, 2010 , Article)
A redundancy balancing technique for the five-level diode-clamped inverter is presented, which balances the four dc-link capacitor voltages at high modulation index and high power factor. The technique is based on dividing ...
DC-link capacitor voltage balancing for a five-level diode-clamped active power filter using redundant vectors
(2013 , Article)
This paper investigates the compensation and modulation processes of the five- level diode-clamped active power filter, compensating a three-phase rectified resistor-inductor load with redundant vectors. From the analysis, ...
Switched mode power supplies for charge-up, discharge and balancing dc-link capacitors of diode-clamped five-level inverter
(
IET
, 2010 , Article)
Inductor switch mode power supplies (SMPS) operated in a discontinuous inductor current mode are used to balance the dc-link capacitor voltages of a diode-clamped five-level inverter. The SMPS concept is extended to charge ...