Plackett-Burman and Box-Behnken designs as chemometric tools for micro-determination of L-Ornithine
المؤلف | Elazazy M.S. |
المؤلف | El-Hamshary M. |
المؤلف | Sakr M. |
المؤلف | Al-Easa H.S. |
تاريخ الإتاحة | 2019-11-04T05:19:30Z |
تاريخ النشر | 2018 |
اسم المنشور | Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy |
المصدر | Scopus |
الرقم المعياري الدولي للكتاب | 1386-1425 |
الملخص | Plackett-Burman (PB) and Box-Behnken (BB) screening and response surface factorial designs were used to evaluate spectrophotometric and spectrofluorimetric approaches for the determination of l-Ornithine (ORN) as per se and in dietary supplements. Both approaches were based on the derivatization of the primary amino group of ORN via Hantzsch condensation reaction producing yellow coloured adducts (dihydrolutidine derivative). The reaction product was determined spectrophotometrically (method A) at λmax = 327 nm and spectrofluorimetrically (method B) at 480 nm (λem) after excitation at 325 nm (λex). A multivariate scheme was tailored to investigate the process numerical variables; reaction temperature, heating time, reagent volume, and pH implementing PB as a screening design followed by BB as an optimization strategy. Categorical factors including diluting solvent and sequence of addition were kept invariable. Responses of the reaction systems were the maximum absorbance (Y1) and maximum fluorescence intensity (Y2), correspondingly. Quality tools as well as ANOVA testing, before and after response transformation were used to decide upon the substantial variables. Following the optimization of reaction variables using desirability plots, calibration graphs were found to be rectilinear in the range of 6–14 μg/mL and 0.4–1.2 μg/mL for methods A and B, respectively. Both methods proved to be sensitive with detection limits (DL) of 337 and 85 ng/mL, and quantitation limits (QL) of 1086 and 283 ng/mL, for methods A and B, respectively. An interference study was performed using potential foreign species. No significant interference effect was observed on any of the proposed procedures. System performance was addressed following ICH guidelines and considering parameters such as linearity, detection and quantification limits, accuracy and precision, robustness and specificity. |
راعي المشروع | This work was supported by Qatar University, College of Arts and Sciences internal grant No. QUUG-CAS-DCES-14/15–12, 2015–2016. The findings achieved herein are solely the responsibility of the authors. |
اللغة | en |
الناشر | Elsevier B.V. |
الموضوع | Box-Behnken design Chemometrics Dietary supplements Hantzsch reaction L-Ornithine Method validation Plackett-Burman design Spectrofluorimetry Spectrophotometry |
النوع | Article |
الصفحات | 397-406 |
رقم المجلد | 193 |
تحقق من خيارات الوصول
الملفات في هذه التسجيلة
الملفات | الحجم | الصيغة | العرض |
---|---|---|---|
لا توجد ملفات لها صلة بهذه التسجيلة. |
هذه التسجيلة تظهر في المجموعات التالية
-
الكيمياء وعلوم الأرض [587 items ]