An Innovative Structural Solution to Failed Stabilized Earth Embankment in Multilevel Interchange
الملخص
This paper summarizes a case study of a failure in a mechanically stabilized earth
retaining wall ramp heading to a multilevel interchange. The failure was caused by a
washout cavity resulting from a long-term leakage from unknown existing wet utilities
adjacent to the mechanically stabilized earth retaining wall. The interchange is located
within a very congested traffic area and has limited right of way and working space. The
methodology of investigation, root cause of the failure, evaluation of the existing structure
and innovative solution to the problem within fast-track design and construction are
studied in this paper. Due to the necessity of maintaining the existing traffic movements
at the interchange which is located at one of the most important expressway routes,
timely rectification methodology was conceived, designed and implemented. This paper
is prepared only to evaluate the technical innovative alternatives, solutions and fast-track
construction without mentioning the interchange and project area.