Construction of Modified CuO-Co3O4-ZnO Electrode for Acetone Detection in Breath
Date
2020Author
Elsafi, Alaa MohamedKrishnasamy, Vinotha
Kannan, Karthik
Cabibihan, John-John
Al-Ali, Abdulaziz Khalid
Malik, Rayaz A.
Sadasivuni, Kishor Kumar
...show more authors ...show less authors
Metadata
Show full item recordAbstract
Acetone in breath can be used as a biomarker for noninvasive detection of diabetes. The acetone level in breath is substantially high for diabetic patients. In this study, mixed metal oxide nanocomposite of CuO-Co3O4 -ZnO was used for the electrochemical detection of acetone in artificial breath solution. The structural and morphological characterization of synthesized nanocomposite was done by XRD, RAMAN and SEM (EDAX) analysis. The electrochemical study was performed and the metal oxide modified electrode showed the sensitivity of 6.52 ?A cm-2 ppm-1 towards the detection of acetone in the artificial solution.
DOI/handle
http://hdl.handle.net/10576/16633Collections
- Theme 1: Energy, Environment & Resource Sustainability [108 items ]