عرض بسيط للتسجيلة

المؤلفYounes, Salma
المؤلفAl-Jighefee, Hadeel
المؤلفShurrab, Farah
المؤلفAl-Sadeq, Duaa W.
المؤلفYounes, Nadin
المؤلفDargham, Soha R.
المؤلفAl-Dewik, Nader
المؤلفQotba, Hamda
المؤلفSyed, Mohamed
المؤلفAlnuaimi, Ahmed
المؤلفYassine, Hadi M.
المؤلفTang, Patrick
المؤلفAbu-Raddad, Laith J.
المؤلفNasrallah, Gheyath K.
تاريخ الإتاحة2021-01-27T10:59:44Z
تاريخ النشر2020-01-25
اسم المنشورMicroorganisms
المعرّفhttp://dx.doi.org/10.3390/microorganisms9020245
الاقتباسYounes, S.; Al-Jighefee, H.; Shurrab, F.; Al-Sadeq, D.W.; Younes, N.; Dargham, S.R.; Al-Dewik, N.; Qotba, H.; Syed, M.; Alnuaimi, A.; et al. Diagnostic Efficiency of Three Fully Automated Serology Assays and Their Correlation with a Novel Surrogate Virus Neutralization Test in Symptomatic and Asymptomatic SARS-COV-2 Individuals. Microorganisms 2021, 9, 245. https:// doi.org/10.3390/microorganisms 9020245
معرّف المصادر الموحدhttp://hdl.handle.net/10576/17467
معرّف المصادر الموحدhttp://dx.doi.org/10.3390/microorganisms9020245
الملخصAbstract: To support the deployment of serology assays for population screening during the COVID-19 pandemic, we compared the performance of three fully automated SARS-CoV-2 IgG assays: Mindray CL-900i® (target: spike [S] and nucleocapsid [N]), BioMérieux VIDAS®3 (target: receptor-binding domain [RBD]) and Diasorin LIAISON®XL (target: S1 and S2 subunits). A total of 111 SARS-CoV-2 RT-PCR- positive samples collected at ≥ 21 days post symptom onset, and 127 prepandemic control samples were included. Diagnostic performance was assessed in correlation to RT-PCR and a surrogate virus-neutralizing test (sVNT). Moreover, cross-reactivity with other viral antibodies was investigated. Compared to RT-PCR, LIAISON®XL showed the highest overall specificity (100%), followed by VIDAS®3 (98.4%) and CL-900i® (95.3%). The highest sensitivity was demonstrated by CL-900i® (90.1%), followed by VIDAS®3 (88.3%) and LIAISON®XL (85.6%). The sensitivity of all assays was higher in symptomatic patients (91.1–98.2%) compared to asymptomatic patients (78.4–80.4%). In correlation to sVNT, all assays showed excellent sensitivities (92.2–96.1%). In addition, VIDAS®3 demonstrated the best correlation (r = 0.75) with the sVNT. The present study provides insights on the performance of three fully automated assays, which could help diagnostic laboratories in the choice of a particular assay according to the intended use
اللغةen
الناشرMDPI
الموضوعCOVID-19
SARS-CoV-2
serology
sensitivity
specificity
neutralizing antibodies
surrogate virus neutralization test (sVNT)
العنوانDiagnostic Efficiency of Three Fully Automated Serology Assays and Their Correlation with a Novel Surrogate Virus Neutralization Test in Symptomatic and Asymptomatic SARS-COV-2 Individuals
النوعArticle
رقم المجلد9
dc.accessType Open Access


الملفات في هذه التسجيلة

Thumbnail

هذه التسجيلة تظهر في المجموعات التالية

عرض بسيط للتسجيلة