عرض بسيط للتسجيلة

المؤلفPihikova, Dominika
المؤلفKasak, Peter
المؤلفKubanikova, Petra
المؤلفSokol, Roman
المؤلفTka, Jan
تاريخ الإتاحة2021-07-05T11:03:41Z
تاريخ النشر2016
اسم المنشورAnalytica Chimica Acta
المصدرScopus
معرّف المصادر الموحدhttp://dx.doi.org/10.1016/j.aca.2016.06.043
معرّف المصادر الموحدhttp://hdl.handle.net/10576/21174
الملخصElectrochemical detection method allowing to detect prostate-specific antigen (PSA), a biomarker of prostate cancer (PCa), with PSA glycoprofiling was applied in an analysis of PCa serum samples for the first time. Electrochemical impedance spectroscopy (EIS) as a label-free method with immobilized anti-PSA was applied for PSA detection and lectins to glycoprofile captured PSA on the same surface. A proper choice of blocking agent providing high selectivity of biosensor detection with the immobilized anti-PSA antibody was done. The biosensor could detect PSA down to 100 ag/mL with a linear concentration working range from 100 ag/mL up to 1 μg/mL, i.e. 10 orders of concentration magnitude and the sensitivity of (5.5 ± 0.2)%/decade. The results showed that a commercial carbo-free blocking solution was the best one, reducing non-specific binding 55-fold when compared to the immunosensor surface without any blocking agent applied, while allowing to detect PSA. The biosensor response obtained after addition of lectin (i.e. proportional to the amount of a particular glycan on PSA) divided by the biosensor response obtained after incubation with a sample (i.e. proportional to the PSA level in the sample) was applied to distinguish serum samples of PCa patients from those of healthy individuals. The results showed that Maackia amurensis agglutinin (MAA) recognizing α-2,3-terminal sialic acid can be applied to distinguish between these two sets of samples since the MAA/PSA response obtained from the analysis of the PCa samples was significantly higher (5.3-fold) compared to the MAA/PSA response obtained by the analysis of samples from healthy individuals. Thus, combined analysis of serological PSA levels together with PSA glycoprofiling of aberrant glycosylation of PSA (i.e. increase in the level of α-2,3-terminal sialic acid) has a potential to improve detection of PCa.
راعي المشروعThis publication was made possible by NPRP grant # NPRP-6-381-1-078 from the Qatar National Research Fund (a member of Qatar Foundation). The statements made herein are solely the responsibility of the authors. The research leading to these results received funding from the European Research Council under the European Union's Seventh Framework Programme (FP/2007-2013)/ERC Grant Agreement no. 311532 and this work has received funding from the European Union's Seventh Framework Program for research, technological development and demonstration under grant agreement no. 317420 . We are grateful to Natalia Kopuncova (Department of Urology, University Medicine Greifswald, Germany) for her help.
اللغةen
الناشرElsevier B.V.
الموضوعBiosensors
Electrochemical impedance spectroscopy
Lectins
Prostate cancer
Prostate-specific antigen
العنوانAberrant sialylation of a prostate-specific antigen: Electrochemical label-free glycoprofiling in prostate cancer serum samples
النوعArticle
الصفحات72-79
رقم المجلد934


الملفات في هذه التسجيلة

الملفاتالحجمالصيغةالعرض

لا توجد ملفات لها صلة بهذه التسجيلة.

هذه التسجيلة تظهر في المجموعات التالية

عرض بسيط للتسجيلة