عرض بسيط للتسجيلة

المؤلفSengamalai, Usha
المؤلفRamasamy, Palanisamy
المؤلفThentral, Thamizh
المؤلفBalasubramani, Karthikeyan
المؤلفAlagarsamy, Manjunathan
المؤلفMuthusamy, Suresh
المؤلفPanchal, Hitesh
المؤلفSachithanandam, Mayurappriyan Pudupalayam
المؤلفSadasivuni, Kishor Kumar
تاريخ الإتاحة2022-03-23T06:35:49Z
تاريخ النشر2021
اسم المنشورEnergy Sources, Part A: Recovery, Utilization and Environmental Effects
المصدرScopus
المعرّفhttp://dx.doi.org/10.1080/15567036.2021.1980157
معرّف المصادر الموحدhttp://hdl.handle.net/10576/28599
الملخصMulti-level inverters have outstanding construction, making it feasible to achieve high voltage levels with less THD value. These harmonics can be mitigated by decreasing the number of voltage switches and DC links in the modified cascaded H-bridge multi-level inverter. This research deals with the novel 15-level inverter and reducing the number of power switches. The proposed work consists of three simulation circuits, one with 10 switches and the second with 12 switches. The mitigation of harmonics, voltage stress, and common-mode voltage is achieved with the help of modifying the pulses of the switches in the proposed 10 switches topology. Additionally, a filter is applied at the terminal to reduce the overall THD value for variable AC load applications. The multi-level inverter can generate the high-level output with less harmonics, losses, and common-mode voltage with the help of low switching frequencies. These types of a multi-level inverters are used in renewable energy applications. Finally, the simulation of a 15-level novel inverter is carried out with the help of MATLAB/Simulink software and compared with the conventional cascaded H-bridge multi-level inverter. The total harmonics distortion for modified CHBMI with 12 switches with or without filter and modified CHBMI with 10 switches with or without are mitigated as 13.53, 6.91, 12.86, and 4.56, respectively, compared to the conventional method with 28 switches. The proposed method is implemented in the hardware to validate the simulated results of the proposed topology.
اللغةen
الناشرTaylor and Francis Ltd.
الموضوعCascaded H bridge
common-mode voltage
multi-level inverter
pulse width modulation
total harmonic distortion
voltage stress
العنوانA simplified methodology for mitigating the harmonics and common-mode voltage using multi-level inverters for renewable energy applications
النوعArticle