Intravenous fluids in hot pre-hospital environments: Thermal and physical stability of normal saline after exposure to simulated stress conditions
عرض / فتح
التاريخ
2022المؤلف
Rachid, OusamaAkkbik, Mohammed
Makhlouf, Ahmed
Moslih, Ayad
Al Shaikh, Loua
Alinier, Guillaume
...show more authors ...show less authors
البيانات الوصفية
عرض كامل للتسجيلةالملخص
Background: Normal saline 0.9 % (NS) is the most widespread crystalloid used as a life-saving intravenous (IV) fluid. 1 NS contains sodium and chloride in equal concentrations and is subject to thermal stress conditions while stored and transported by clinicians in the pre-hospital environment. 2 This study aimed to investigate the effect of high-temperature exposure on NS bags used by the Hamad Medical Corporation Ambulance Service in Qatar. Methods: Five-hundred mL polyolefin NS soft bags (Qatar-Pharma, BN:1929013008) were divided into 4 groups of 24 each and stored at constant temperature (22, 50, or 70°C), or subjected to a temperature of 70°C for 8 hours followed by 22°C for 16 hours repeatedly over 28 days. Inspection and chromatographic analysis of the bags was performed at 0, 12, 24, 48, and 72 hours in the 72-hour study, and at 1, 2, 3, and 4 weeks in the 28-day study. Results: NS bags slightly bulged at 50°C and significantly bulged at 70°C or in the long experiment with temperature variation (Figure 1). During the exposure period, there was no discoloration, turbidity, or leaching of plastic components observed in the NS fluid. The pH readings were 5.59 ± 0.08 (22°C-Control sample), 5.73 ± 0.04 (50°C), 5.86 ± 0.02 (70°C), and 5.79 ± 0.03 following prolonged temperature variation. The sodium and chloride levels for the short-term study ranged from 100.2 ± 0.26% to 107.9 ± 0.75% and from 99.04 ± 0.76 to 102.11 ± 1.71%, and for the long-term study they ranged from 101.93 ± 0.90% to 111.27 ± 2.61 and from 99.05 ± 0.94% to 110.95 ± 1.63%; respectively (Figure 2) in comparison to manufacturer stated concentrations. Conclusion: There was no evidence to suggest that the NS fluid inside the PO bags is physically and chemically different when exposed up to 28 days to 50°C, 70°C, and prolonged temperature variations compared to 22°C. These simulated conditions are subject to further testing under real-life pre-hospital care emergency conditions in a hot country.
معرّف المصادر الموحد
https://doi.org/10.5339/jemtac.2022.qhc.60DOI/handle
http://hdl.handle.net/10576/28948المجموعات
- أبحاث الطب [1518 items ]
- أبحاث الصيدلة [1315 items ]