The effect of nanocoatings of SiO2, TiO2, and ZrO2 on titanium-porcelain bonding
Author | Atsu S.S. |
Author | Aksan M.E. |
Author | Bulut A.C. |
Author | Tamimi F. |
Available date | 2022-05-31T19:01:19Z |
Publication Date | 2021 |
Publication Name | Journal of Prosthetic Dentistry |
Resource | Scopus |
Identifier | http://dx.doi.org/10.1016/j.prosdent.2021.04.023 |
Abstract | Statement of problem: Durable titanium-porcelain bonding is challenging because of the formation of a thick oxide layer on the surface during porcelain firing. Purpose: The purpose of this in vitro study was to evaluate how atomic layer deposition (ALD) of different oxide coatings affected titanium-porcelain bonding and failure types. Material and methods: Forty-four airborne-particle abraded Type-2 titanium specimens were coated by ALD with either SiO2, TiO2, or ZrO2 (n=11) at a thickness of 30 nm, whereas control specimens were left uncoated (n=11) (airborne-particle abraded only). The surface roughness of the specimens was analyzed with a profilometer before applying porcelain (Vita Titankeramic). Titanium-porcelain bonding was analyzed by using a 3-point bend test. Surface properties and titanium-porcelain interfaces were examined under scanning electron microscopy combined with energy-dispersive spectroscopy, and failure types were evaluated by using a stereomicroscope. Surface roughness and bond strength data were analyzed by 1-way ANOVA and Tukey HSD tests. Failure type data were analyzed by the Fisher-Freeman-Halton exact test (�=.05). Results: All nanocoatings increased surface roughness values, but only TiO2 and ZrO2 coatings showed statistically significant higher roughness than the control surfaces (P<.001). Specimens coated with SiO2 (28.59 �4.37 MPa) and TiO2 (26.86 �3.66 MPa) presented significantly higher bonding strength than control (22.04 �4.59 MPa) specimens (P<.01). Fracture types of different groups were not statistically different (P>.05). Conclusions: Nanocoating titanium surfaces with SiO2 and TiO2 by using the ALD technique significantly improved titanium-porcelain bonding. |
Language | en |
Publisher | Mosby Inc. |
Subject | dental porcelain silicon dioxide titanium titanium dioxide dental bonding materials testing scanning electron microscopy surface property Dental Bonding Dental Porcelain Materials Testing Microscopy, Electron, Scanning Silicon Dioxide Surface Properties Titanium |
Type | Article |
Pagination | 2220-22200000000 |
Issue Number | 2 |
Volume Number | 126 |
Check access options
Files in this item
Files | Size | Format | View |
---|---|---|---|
There are no files associated with this item. |
This item appears in the following Collection(s)
-
Dental Medicine Research [338 items ]