An Improved Fault Tolerant Five-Phase Induction Machine Using A Combined Star/Pentagon Single Layer Stator Winding Connection
المؤلف | Abdel-Khalik, Ayman S. |
المؤلف | Elgenedy, Mohamed A. |
المؤلف | Ahmed, S. |
المؤلف | Massoud, Ahmed M. |
تاريخ الإتاحة | 2015-06-23T09:59:34Z |
تاريخ النشر | 2015-04 |
اسم المنشور | IEEE Transactions on Industrial Electronics |
الاقتباس | Abdel-Khalik, A.S.; Elgenedy, M.A.; Ahmed, S.; Massoud, A.M., "An Improved Fault Tolerant Five-Phase Induction Machine Using A Combined Star/Pentagon Single Layer Stator Winding Connection," Industrial Electronics, IEEE Transactions on |
الرقم المعياري الدولي للكتاب | 0278-0046 |
الملخص | One of the main merits offered by multiphase machines is their high fault-tolerant capability. Literature has demonstrated that the performance of multiphase induction machines under fault conditions is affected by the employed stator winding connection. In open-loop controlled five-phase machines, the star connection is favorable under healthy conditions while the pentagon connection is favorable and yields a lower derating factor under the open phase condition. In this paper, a new combined star/pentagon single layer winding layout that combines the advantages of both star and pentagon connections is proposed for a five-phase induction machine. Although the proposed winding is intrinsically an asymmetrical 10-phase machine, the proposed connection allows for only five-phase terminals. Moreover, the proposed winding not only yields better flux distribution compared to a conventional single layer winding, but also provides a complete cancellation of the third order harmonic flux component caused by the induced third sequence currents due to the saturation effect and/or under unbalanced operation. Hence, the machine losses are decreased, which improves the overall machine efficiency. For the healthy case, the machine is similar to a conventional star connected five-phase machine. However, with one phase open, the proposed connection results in a lower derating factor compared to conventional connections for both open-loop and optimal current control techniques. A 1kW prototype machine is used for experimental verification. |
اللغة | en |
الناشر | IEEE |
الموضوع | Derating factors Multiphase machine pentagon connection |
النوع | Article |
الصفحات | 618-628 |
الملفات في هذه التسجيلة
الملفات | الحجم | الصيغة | العرض |
---|---|---|---|
لا توجد ملفات لها صلة بهذه التسجيلة. |
هذه التسجيلة تظهر في المجموعات التالية
-
الهندسة الكهربائية [2649 items ]