Show simple item record

AuthorIslam, Mohammad T.
AuthorIslam, Md T.
AuthorSamsuzzaman, Md
AuthorKibria, Salehin
AuthorChowdhury, Muhammad E. H.
Available date2023-04-17T06:57:46Z
Publication Date2021
Publication NameDiagnostics
ResourceScopus
URIhttp://dx.doi.org/10.3390/diagnostics11030470
URIhttp://hdl.handle.net/10576/41984
AbstractMicrowave imaging (MI) is a consistent health monitoring technique that can play a vital role in diagnosing anomalies in the breast. The reliability of biomedical imaging diagnosis is substantially dependent on the imaging algorithm. Widely used delay and sum (DAS)-based diagnosis algorithms suffer from some significant drawbacks. The delay multiply and sum (DMAS) is an improved method and has benefits over DAS in terms of greater contrast and better resolution. However, the main drawback of DMAS is its excessive computational complexity. This paper presents a compressed sensing (CS) approach of iteratively corrected DMAS (CS-ICDMAS) beamforming that reduces the channel calculation and computation time while maintaining image quality. The array setup for acquiring data comprised 16 Vivaldi antennas with a bandwidth of 2.70-11.20 GHz. The power of all the channels was calculated and low power channels were eliminated based on the compression factor. The algorithm involves data-independent techniques that eliminate multiple reflections. This can generate results similar to the uncompressed variants in a significantly lower time which is essential for real-time applications. This paper also investigates the experimental data that prove the enhanced performance of the algorithm. 2021 by the authors. Licensee MDPI, Basel, Switzerland.
SponsorAcknowledgments: This work was supported by Grant NPRP12S-0227-190164 from the Qatar National Research Fund, a member of Qatar Foundation, Doha, Qatar and the internal grant of Qatar University QUST-1-CENG-2021-6 and the claims made herein are solely the responsibility of the authors. This work was supported by the Ministry of Higher Education of Malaysia (MOHE), grant code No. FRGS/1/2018/TK04/UKM/01/3. This work was supported by Grant NPRP12S-0227-190164 from the Qatar National Research Fund, a member of Qatar Foundation, Doha, Qatar and the claims made herein are solely the responsibility of the authors. Open Access funding provided by the Qatar National Library.
Languageen
PublisherMDPI
SubjectBreast imaging
Compressed sensing
Delay multiply and sum
Iterative correction
Microwave imaging
TitleMicrowave breast imaging using compressed sensing approach of iteratively corrected delay multiply and sum beamforming
TypeArticle
Issue Number3
Volume Number11


Files in this item