عرض بسيط للتسجيلة

المؤلفHall, Kevin
المؤلفLewis, Jeremy
المؤلفMoore, Ann
المؤلفRidehalgh, Colette
تاريخ الإتاحة2023-09-20T08:47:10Z
تاريخ النشر2020
اسم المنشورArchives of Physiotherapy
المصدرScopus
الرقم المعياري الدولي للكتاب20570082
معرّف المصادر الموحدhttp://dx.doi.org/10.1186/s40945-020-00084-w
معرّف المصادر الموحدhttp://hdl.handle.net/10576/47795
الملخصBackground Although posterior shoulder tightness (PST) has been associated with shoulder pathology and altered glenohumeral joint kinematics, uncertainty remains regarding its cause and definition. To understand the efficacy of treatments for PST, it must be possible to identify people with PST for the purposes of research and clinical decision-making. Clinical tests for PST must demonstrate acceptable levels of measurement reliability in order to identify the condition and to evaluate the response to intervention. There is currently a lack of research describing intersession reliability for measures of PST. The aim of this study was to quantify the inter-session reliability for three clinical tests used to identify PST over a 6–10 week interval. Methods A convenience sample of 26 asymptomatic adult participants (52 shoulders) were recruited from a university setting over a five-month duration. Participants attended the human movement laboratory for measurement of glenohumeral joint internal rotation, horizontal adduction and low flexion on two occasions separated by an interval of 6–10 weeks. Intra-class correlation coefficients were calculated from the mean square values derived from the within-subject, single factor (repeated measures) ANOVA. Test-retest measurement stability was evaluated by calculating the standard error of measurement and the minimum detectable change for each measurement. Results All 3 tests demonstrated good intersession intra-rater reliability (0.86–0.88), and the standard error of measurement (95%) were 7.3° for glenohumeral horizontal adduction, 9.4° for internal rotation, and 6.9° for low flexion. The minimum detectable change for glenohumeral horizontal adduction was 10.2°, internal rotation was 13.3°, and low flexion was 9.7°. Conclusion In this population of people without symptoms, the 3 measures of PST all demonstrated acceptable inter-session reliability. The standard error of measurement and minimum detectable change results can be used to determine if a change in measures of PST are due to measurement error or an actual change over time.
راعي المشروعThis study was supported with a personal research award (KH) from Health Education England Kent, Surrey and Sussex (HEKSS). HEKKS had no input into the design of the study, data collection, analysis, interpretation of data or preparation of this manuscript. This study was supported by a personal research award from Health Education England Kent, Surrey and Sussex. Institutional ethical approval was provided by the University of Brighton, Faculty of Health and Social Science Research Ethics & Governance Committee (FREGC-13-042.R2).
اللغةen
الناشرBioMed Central Ltd
الموضوعBaseball
Baseball Player
Throwing
العنوانPosterior shoulder tightness; an intersession reliability study of 3 clinical tests
النوعArticle
رقم العدد1
رقم المجلد10


الملفات في هذه التسجيلة

Thumbnail

هذه التسجيلة تظهر في المجموعات التالية

عرض بسيط للتسجيلة