Show simple item record

AuthorHaddad, Monoem
AuthorHermassi, Souhail
AuthorAganovic, Zlatan
AuthorDalansi, Feriel
AuthorKharbach, Mariam
AuthorMohamed, Azam Omar
AuthorBibi, Khalid W.
Available date2023-10-23T10:25:29Z
Publication Date2020
Publication NameFrontiers in Physiology
ResourceScopus
URIhttp://dx.doi.org/10.3389/fphys.2020.00957
URIhttp://hdl.handle.net/10576/48758
AbstractThe aim of the study was to assess the validity and reliability of wearable body metric Hexoskin “smart shirt” in measuring heart rate (HR) at pre-exercise and during peak effort in a field test incorporating vigorous movements of the upper body. Measurements were recorded simultaneously using the Hexoskin and Polar Team Pro. Nine male professional handball players (age: 21.8 ± 2.4 years; weight: 83 ± 10.26 kg; height: 1.81 ± 0.09 m; and BMI: 25.17 ± 2.23) volitionally participated in the study by completing two 400 m shuttle run test trials (10 shuttles), each separated by a 48 to 72 h recovery period. Results indicated significant correlations between Hexoskin and Polar Team Pro system in pre-exercise HR. Hexoskin provided erroneous measurements in four of the nine athletes during peak effort. Subsequent correction yielded no consistency between the Polar Team Pro system and Hexoskin between the first and the second trial. Hexoskin showed significant reliability in pre-exercise HR. However, Hexoskin picked up excessive artifact during vigorous physical activity in four of the nine athletes rendering the results in these cases useless. Nevertheless, in athletes where artifact was not an issue, ICC yielded a good estimate. The main findings indicate that Hexoskin has good validity and reliability in measuring pre-exercise HR in handball players and hence may be used with high confidence in slow motion activities. However, vigorous physical activity with jarring multidirectional upper body movements posed a challenge for Hexoskin. © Copyright © 2020 Haddad, Hermassi, Aganovic, Dalansi, Kharbach, Mohamed and Bibi.
SponsorThis publication was supported by Qatar University Student Grant QUST-CAS-SPR-2017-20.
Languageen
PublisherFrontiers Media S.A.
Subjectfield test
monitoring heart rate
Polar Team Pro
validity
wearable telemetry body metrics shirt
TitleEcological Validation and Reliability of Hexoskin Wearable Body Metrics Tool in Measuring Pre-exercise and Peak Heart Rate During Shuttle Run Test in Professional Handball Players
TypeArticle
Volume Number11


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record